User Manual

AirLink P roT1/E 1 R ack M ount C onfiguration W orksheet
P air ID /N am e M aster:
S lave :
S erial N um ber M aste r: S lave :
P air L ocation M aster: S lave :
A ntenn a T ype:
C able Len gth:
P AR AM E T E R V ALU E S M AS T E R S LAV E
Administrative P a ra meters
S ite N am e 60 alph anu m eric chars (null string)
S ite N am e, M aste r:
S ite N am e, S lave :
Tim e m m /d d/yy (defa ult: 01/0 1/91 )
D ate hh:m m :ss (de fault: 00 :00:00 )
P assw o rd 16 alphanum eric chars (null string)
T1 Line P arameters
C od ing B8Z S or A M I
E qua liza tion 0 , 13 3, 26 6, 39 9, or 533
Link P ara meters
A pplication 1. P rim ary m aste r at a hub
2. S eco nda ry m aster at a hu b
3. M aster unit at a repea ter site
4. M aster unit in a P oint-to-Point link
5. S lave u nit at a repea ter site
6. S lave u nit in a po int-to-point link
B urst M od e Duplex o r S im plex (D e fault: D u plex)
P N C o de 1 .. 8 (de fault: 1 )
R F P ow e r Le vel -4 dBm .. 20 dB m (de fault: 0 dBm )
Ala rm Control P arameters
A larm R ep orting R e que st or Immedia te
A larm Leve l Sta tus , A d visory, A larm , or F ault
1-H our E S T hreshold 1 .. 99 9 (se cond s) (de fault: 1 )
1-H our U AS T hreshold 1 .. 99 (seconds) (d efau lt: 1 )
24-H our ES T hreshold 1 .. 9 99 (second s) (de fault: 1 )
24-H our U A S Th resh old 1 .. 99 (second s) (de fault: 1 )
R x P ow er T hre shold -80 .. -40 dB m (de fault: -7 5 dBm )
Tx P o w er Threshold -10 .. 20 d B m (de fault: -6 dBm )