Terminal Configuration
Before connecting the ASCII terminal to the unit, configure the terminal with
the following parameters:
Terminal Mode = VT100
Column = 80
Autowrap = ON
Monitor Mode = OFF
Cursor Keys = Normal
Newline Mode = ON
Character Set = DEC Supplemental
Key Code = ASCII
Break key = ON
Minimum Break Length = 2 character times (17 msec.)
Data/Parity = 8/No Parity
Stop Bits = 1
Transmit Rate = 19200, 9600, 4800, 2400, or 1200 bps
Auto Answerback = OFF
Comm = FDX (No Echo)
RS232 Data Leads Only (RxD and TxD)
Local Echo = OFF
A Break code is recognized by many systems as an attention signal, and most
systems vary as to the length of time Break must be generated before it is
recognized. Most terminals and terminal emulation software allow you to set
the length of the Break signal.
The minimum Break length for the AirLink Pro T1/E1 Rack Mount is two
character times or approximately 17 milliseconds. A longer Break length
(limited by the range available from the setup program of the terminal or
terminal emulation software) has no effect on the AirLink Pro T1/E1 Rack
Mount.
For more information about terminal configuration, see the AirLink Site
Planning Guide.