User Manual

AirLink Pro T1/E1 Rack Mount Installer’s Guide
Specifications
Rev. B - 1/97
B-9
Table B-6
Receiver
Input Impedance 50 nominal. VSWR < 2:1 over the frequency and
temperature range
RF Input Protection +10 dBm continuous without damage
Maximum RF Input Power
Without Causing Dribbling Errors
-25 dBm
Receiver Dynamic Range > 40 dB
Receive Signal Strength ± 2 dB
Receive Level Detector Dynamic range: 40 dB
Accuracy: ± 3 dB
Frequency Band 5.725 to 5.850 GHz
Noise Figure 5.5 dB maximum, measured from the antenna port
RSQ Detector Dynamic Range: 0 - 10
Operating Range: 9 - 10
Receiver Sensitivity (dBm) T1 E1
10
-6
Guaranteed
-80 -78
10
-6
Typical
-82 -80
10
-9
Guaranteed
-77 -75
10
-9
Typical
-79 -77