User Manual

AirLink Pro T1/E1 Rack Mount Installer’s Guide
Messages
Rev. B - 1/97
A-2
General Information
AirLink Pro T1/E1 Rack Mount messages are only accessible through a terminal
device connected to a Terminal port on the AirLink Pro T1/E1 Rack Mount. All
messages are coded with a four-digit alphanumeric code so that higher-level
network management software can detect the message. These messages are
grouped into the following categories:
Fault messages (0xxx)
Alarm messages (4xxx)
Advisory messages (8xxx)
Status messages (Cxxx)
When you enter a query alarms command, the system displays a list of alarm
and event information similar to the following:
AIRLINK T1> query alarms
8: 8001: 20 SEP 1994 15:11:32 QRSS Test Started
7: C006: 20 SEP 1994 15:11:31 All Tests Cleared
6: 8007: 20 SEP 1994 15:09:50 FE Remote Loop Test Started
5: C006: 20 SEP 1994 15:09:50 All Tests Cleared
4: C006: 20 SEP 1994 15:07:51 All Tests Cleared
3: 8001: 20 SEP 1994 15:06:22 QRSS Test Started
2: C006: 20 SEP 1994 15:06:22 All Tests Cleared
1: C000: 20 SEP 1994 14:59:22 Event queue Cleared
When the event queue contains alarm messages, the most recent message is
displayed at the top of the list, with the most recent time and date.
When there are more messages than will fit on one screen, you can page through
the messages by pressing <Return> to go forward one screen, or <B><Return> to
go back one screen. Press <Q> to exit (quit) the event queue display.