User Manual
AirLink Pro T1/E1 Rack MountInstaller’s Guide
Operations and Maintenance
Rev. B - 1/97
4-22
OK
AIRLINK PRO T1/E1>
Site Name: Sunnyvale 1
If you query the status information while the test is running, you can verify
that the test is running:
AIRLINK PRO T1/E1> query status
Site Name: Sunnyvale 2
DTE Loss: NO
Radio Sync Loss: NO
Burst Sync Loss: N/A
Test in Progress: Remote Loop
DTE AIS: OFF
RF AIS: OFF
Tx Fail: NO
Rx Power: -60.5 dBm
Tx Power: 12.0 dBm
Temperature: 5 C
Rack Mount Unit Working with Pro T1 Ruggedized Unit
The following describes the differences between an AirLink Pro T1 Rack Mount
Unit and the AirLink Pro T1 Ruggedized Unit.
• A Ruggedized unit has an option to use an Access Unit, and if the Access
Unit is installed, there is an additional remote loopback command called
"Access Unit Remote Loop."
• A Rack-Mount unit has software set-ability of the E1 Interface (balanced or
unbalanced). A Ruggedized unit does not have this option. This option
appears in the Rack-Mount unit list of "SET" commands.
• A Rack-Mount unit has a two-wire or four-wire Order wire option. The
Ruggedized unit has only two-wire. This option appears in the list of "SET"
commands.
NOTE When an AirLink Pro T1/E1 Rack Mount is operating end-to-end with and AirLink Pro T1/E1
Ruggedized unit, the Order wire option in the Airlink Pro Rack Mount unit MUST be set to
two-wire.