Object ID Group Object Type Access Description
1.3.6.1.4.1.1316.1.1.1.5.1.4 mdrmteRelay1Reserved INTEGER
1.3.6.1.4.1.1316.1.1.1.5.1.5 mdrmteRelay1CurrentState INTEGER read-write The current state of the relay.
Used to activate/deactivate a
relay.
1.3.6.1.4.1.1316.1.1.1.5.1.6 mdrmteRelay1ScriptTable SEQUENCE
1.3.6.1.4.1.1316.1.1.1.5.1.6.1 mdrmteRelay1ScriptEntry SYNTAX
1.3.6.1.4.1.1316.1.1.1.5.1.6.1.
1
mdrmteRelay1ScriptIndex†
6
INTEGER
1.3.6.1.4.1.1316.1.1.1.5.1.6.1.
2
mdrmteRelay1ScriptID INTEGER read-write Defines which of the listed
alarms can cause a relay to
activate.
1.3.6.1.4.1.1316.1.1.1.5.1.6.1.
3
mdrmteRelay1ScriptActiveLocal INTEGER read-write Defines if the script is active or
not for local relay activation.
1.3.6.1.4.1.1316.1.1.1.5.1.6.1.
4
mdrmteRelay1ScriptActiveRemote INTEGER read-write Defines if the script is active or
not for remote relay activation.
1.3.6.1.4.1.1316.1.1.1.5.2 mdrmteRelay2
1.3.6.1.4.1.1316.1.1.1.5.2.1 mdrmteRelay2Label DisplayString read-write A short, descriptive name
indicating the primary function
of the relay, most probably in
terms of the equipment
connected to it.
1.3.6.1.4.1.1316.1.1.1.5.2.2 mdrmteRelay2OpenStateLabel DisplayString read-write A short, descriptive name
indicating the primary function
of the relay in the open state,
most probably in terms of the
equipment connected to it.
1.3.6.1.4.1.1316.1.1.1.5.2.3 mdrmteRelay2ClosedStateLabel DisplayString read-write A short, descriptive name
indicating the primary function
of the relay in the closed state,
most probably in terms of the
equipment connected to it.
1.3.6.1.4.1.1316.1.1.1.5.2.4 mdrmteRelay2Reserved INTEGER
1.3.6.1.4.1.1316.1.1.1.5.2.5 mdrmteRelay2CurrentState INTEGER read-write The current state of the relay.
Used to activate/deactivate a
relay.
1.3.6.1.4.1.1316.1.1.1.5.2.6 mdrmteRelay2ScriptTable SEQUENCE
1.3.6.1.4.1.1316.1.1.1.5.2.6.1 mdrmteRelay2ScriptEntry SYNTAX
1.3.6.1.4.1.1316.1.1.1.5.2.6.1.
1
mdrmteRelay2ScriptIndex INTEGER
1.3.6.1.4.1.1316.1.1.1.5.2.6.1.
2
mdrmteRelay2ScriptID INTEGER read-write Defines which of the listed
alarms can cause a relay to
activate.
1.3.6.1.4.1.1316.1.1.1.5.2.6.1.
3
mdrmteRelay2ScriptActiveLocal INTEGER read-write Defines if the script is active or
not for local relay activation.
1.3.6.1.4.1.1316.1.1.1.5.2.6.1.
4
mdrmteRelay2ScriptActiveRemote INTEGER read-write Defines if the script is active or
not for remote relay activation.
1.3.6.1.4.1.1316.1.1.1.6 mdrmteOptoInputs
1.3.6.1.4.1.1316.1.1.1.6.1 mdrmteOptoInput1
1.3.6.1.4.1.1316.1.1.1.6.1.1 mdrmteOptoInput1Label DisplayString read-write A short, descriptive name
indicating the primary function
of the contact-closure input in
6
Relay scripting is not activated in Versions 1.00 & 2.00, 01, 02 of the IU firmware release.