User Manual

SC5800 User Manual
89
Object ID Group Object Type Access Description
defines the receive frequency
of the Outdoor Unit.
1.3.6.1.4.1.1316.1.1.1.2.2.13 mdrmteNonAutoBandPlan INTEGER read-write Same as mdrMTEBandPlan
setting in this MIB group except
“auto recovery” is not enabled -
this allows control of the
Outdoor Unit frequencies
without the “auto recovery”
feature attempting to intervene
and re-establish setup of an
operational RF Link.
1.3.6.1.4.1.1316.1.1.1.2.2.14 mdrmteNonAutoTxFreqPlanD INTEGER read-write Same as mdrTxFrequencyPlanD
setting in this MIB group except
“auto recovery” is not enabled -
this allows control of the
Outdoor Unit Plan D frequencies
without the “auto recovery”
feature attempting to intervene
and re-establish setup of an
operational RF Link.
1.3.6.1.4.1.1316.1.1.1.2.2.15 mdrmteNonAutoRxFreqPlanD INTEGER read-write Same as mdrTxFrequencyPlanD
setting in this MIB group except
“auto recovery” is not enabled -
this allows control of the
Outdoor Unit Plan D frequencies
without the “auto recovery”
feature attempting to intervene
and re-establish setup of an
operational RF Link.
1.3.6.1.4.1.1316.1.1.1.2.2.16 mdrmteNonAutoTxPower INTEGER read-write Same as mdrTxPower setting in
this MIB group except “auto
recovery” is not enabled - this
allows control of the Outdoor
Unit power level setting without
the “auto recovery” feature
attempting to intervene and re-
establish setup of an operational
RF Link.
1.3.6.1.4.1.1316.1.1.1.2.3 mdrmteServiceChannel
1.3.6.1.4.1.1316.1.1.1.2.3.1 mdrmteScDataRate
3
INTEGER read-write Bit rate used across the
wayside service channel link.
1.3.6.1.4.1.1316.1.1.1.2.3.2 mdrmteScDataBits
4
INTEGER read-write The data width - can be 7 or 8
bits.
1.3.6.1.4.1.1316.1.1.1.2.3.3 MdrmteScParity INTEGER read-write Serial channel - set to none, odd
or even.
1.3.6.1.4.1.1316.1.1.1.2.3.4 MdrmteScStopBits INTEGER read-write The number of stop bits can be
set to 1 or 2.
1.3.6.1.4.1.1316.1.1.1.2.3.5 mdrmteScFlowControl INTEGER read-write Either hardware or no flow
control is used.
1.3.6.1.4.1.1316.1.1.1.2.3.6 mdrmteScStatusDump INTEGER read-write Allows the wayside service
(serial) channel to be used as a
diagnostics port [deprecated].
1.3.6.1.4.1.1316.1.1.1.2.4 MdrmteGeneral
1.3.6.1.4.1.1316.1.1.1.2.4.1 MdrmteStationName DisplayString read-write The station name is stored in
the Indoor Unit in non-volatile
3
Fixed at 115.2kbps in Version 1.00 and 2.00, 2.01, 2.02 IU firmware releases.
4
Serial setting – 8 bits, no parity, 1 stop bit