Installation Manual
2
Vertically Mounted:
The sensor comes assembled
and ready for vertical cover
plate mounting, as shown in
the illustration below.
Attach mounting post to the cover plate:
Make sure that the O-ring is on the threaded end of the mounting post
before installing.
O-ring
Lightly screw the
mounting post into
the cover plate by
rotating the sensor.
Adjust the sensor
to the desired
angle, then tighten
the locking ring.
Locking ring and collar
must be securely seated
against the cover plate
locking ring.
Loosen the two screws at the
back of the sensor.
Rotate the sensor
housing 180°.
Replace and tighten the screws.
1
2
3
MOTION SENSOR PLACEMENT
Mounting Options
• Install onto a standard 4” round outdoor junction box.
• Mount to a flat, stable, vibration-free surface.
• Mount vertically or horizontally, usually to a wall, ceiling or under an eave.
Careful consideration must be given to sensor placement. PIR sensors detect the difference between infrared energy in motion and the
background space. To be detected, a person or vehicle must be within the sensor’s coverage pattern and have an unobstructed view of
the sensor.
Horizontally Mounted:
For horizontal mounting, such as under eaves, rotate the sensor housing as shown in the diagrams below. Make sure that the
gasket is seated properly.
90
9.5ft
(3m)
25ft
(8m)
52.5f
t
(16m)
8ft
(2.4m)
Top
View
Side
View
EW-200
270° coverage
Masking:
Opaque adhesive tape is supplied
so that sections of the sensor’s
lens can be masked to restrict
coverage in unwanted areas.
COVERAGE PATTERN (CONT’D)