User guide
2
System Specifications
Maximum Pressure: 125psi (8.6 bar)
Maximum Temperature: 100°F (38°C)
Inlet/Outlet Connections: ½" (15mm) FNPT
Maximum Flow Rate: 2 GPM
Filter Cartridge Life Span 
Filter cartridges should be changed at 6,000 gallons, 15psi overall 
system pressure drop at normal flow rate, or 6 months, whichever 
comes first. 
Please note: Cartridge capacities are estimates and may be less 
depending on incoming water quality. Cartridges should be changed 
at least every 6 months. 
Notice to Installer
• Do not discard this manual after installation. This manual contains 
important operation, maintenance and precautionary information. 
Please present this manual to the user/owner/operator after instal-
lation.
• It is strongly suggested that you read this manual before installing 
system to ensure the best possible installation.
• Installation must comply with all local and state plumbing codes 
and regulations. 
• Connect the system to cold water supply only. Water Temperature 
cannot exceed 100°F (38°C)
• System must be installed in a vertical, upright and level position. 
• Do not use with water that is microbiologically unsafe or of un-
known water quality.
• Notice to user/owner/operator: Please retain this manual for future 
reference for parts, maintenance, or troubleshooting.
• It is recommended that all personnel responsible for operation and 
maintenance of this product read the precautions, maintenance, 
and operation sections of this manual. 
Installation Precautions
• Do not install system on line pressure above 125psi (8.6 bar).
• Do not install the system on a hot water line. Failure to limit the 
water temperature to 100°F (38°C) can result in housing failure and 
property damage.
• Do not connect the system backwards with the feed water line 
connected to the outlet. 
• Do not use liquid pipe thread compounds for threaded connec-
tions. Use Teflon
®
 tape only.
• Do not solder plumbing connections that are attached to the hous-
ings or inlet/outlet fittings. System damage may occur due to high 
temperature.
• Do not allow the system to freeze. Turn off water supply and drain 
the system if temperature falls below 32°F (0°C). 
• Do not install system in direct sunlight or where the system will be 
exposed to harsh chemicals or may be subjected to being hit by 
moving equipment, carts, mops, or any other item that may cause 
damage. 
• Allow 3" (76mm) minimum clearance under the housings for lter 
replacement. 
• If water hammer is evident, install water hammer arrestors before 
the system. 
• Do not over tighten tting connections. 
• Always back up valves and ttings with a wrench when installing 
fittings to avoid over tightening or loosening existing fittings. 
• Do not install the unit behind equipment where it may be difcult to 
access the system for future filter replacements. 
Position the system in a suitable location. The direction of flow 
through the system is left to right. Keep this in mind when determin-
ing installation locations. Do not mount the system near any source 
of heat. Also do not mount this system over anything that may be 
adversely affected by water. 
Replacement Filter Pack
MODEL FREQUENCY DESCRIPTION
PWFPKICE1 6 Months 10" Sediment filter
10" Carbon Block filter
10" Phosphate filter
Note: Water conditions may require more frequent cartridge replacement
Teflon
®
 is a registered trademark of E.I. Dupont de Nemours & Company.