Installation/Feedwater Parameters
Location: Indoors (Protect from direct sunlight)
Minimum inlet pressure: 30 psig
Maximum operating pressure: 80 psig
Minimum water temperature: 34°F (1°C)
Maximum water temperature: 110°F (43°C)
pH Range 6.0-9.0
Iron Concentration Maximum 10 PPM
Manganese Concentration Maximum 5 PPM
Hydrogen Sulfide Concentration Maximum 3 PPM
C
A
B
D
E
Dimensions - Weights
ES-WQ-PWBWIRON 1225 © 2012 Watts
USA: Tel. (800) 224-1299 • www.watts.com
Canada: Tel. (888) 208-8927 • www.watts.ca
A Watts Water Technologies Company
MoDEl VAlVE MINERAl TANK MEDIA CUBIC GARNET No.12 SERVICE FloW PRESSURE DRoP BACK WASH FlooR SPACE
SIzE FooT (lBS) (GPM) (PSI) (GPM) (l X W X H)
PWBWIRON1 Time Clock 9" x 48" 1 14 6 <15 7 16" x 15" x 55"
PWBWIRON15 Time Clock 10" x 54" 1.5 14 9 <15 8 16" x 15" x 62"
PWBWIRON2 Time Clock 12" x 52" 2 42 12 <25 12 17" x 15" x 60"
PWBWIRON3 Time Clock 13" x 65" 3 56 18 <25 15 18" x 15" x 74"
PART No. TANK IN oUT oVERAll HEIGHT oVERAll DEPTH SHIPPING WEIGHT
(A&B) (E) (E) (C) (D) lbs. kgs.
PWBWIRON1 9" x 48" 51" 51" 57" 16" 150 68
PWBWIRON15 10" x 54" 57" 57" 63" 16" 207 94
PWBWIRON2 12" x 52" 56" 56" 61" 16" 295 134
PWBWIRON3 13" x 65" 67" 67" 73" 16" 493 224
Power
Voltage: 120VAC
Frequency: 60Hz
Note: Peak service flow rate is for intermittent use only and is not to be interpreted as continuous service flow rate capability. These
systems are designed to treat the domestic water used in a single family dwelling. For irrigation water treatment or higher volume
applications please contact your Watts representative.