The H2O-DWCFL100 system has been tested according to NSF/ANSI 42, 53, for reduction of the substances listed
below. The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specied in NSF/ANSI 42 and 53, and
substantiated by test data. This system is certied to NSF/ANSI standard 372 for ‘lead free’ compliance.
Performance Data Sheet
Watts Pure H2O
In U.S.-Watts Regulator Co.,
N. Andover, MA 01845 (Watts.com);
In Canada-Watts Water Technologies (Canada), Inc., Toronto, ON M5J3G6 (Watts.ca)
Lead Filtration System - H2O-DWCFL100
WARNING
!
GENERAL USE CONDITIONS
1: System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe
quality. DO NOT use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before
or after the system. While testing was performed under standard laboratory conditions, actual performance may vary.
Systems certied for cyst reduction may be used on disinfected waters that may contain lterable cysts.
2: Operating Temperature: Maximum 100° F (38° C) Minimum 35° F (1.7° C)
3: Operating Water Pressure: Maximum 125-psi (861.85kpa) Minimum 10-psi (69kpa)
4: Maximum Flow Rate: 1.5 gpm (5.7 lpm)
5: Rated Capacity Lead: 4,000 gallons (15,142 liters)
6: Rated Capacity Cyst: 4,000 gallons (15,142 liters)
7: Rated Capacity Chlorine: 4,000 gallons (15,142 liters)
8: Rated Capacity Particulate (sediment): 4,000 gallons (15,142 liters)
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVAL:
Depending on incoming feed water conditions replacement time frame may vary.
Description Model / Part Number Change time Frame
Lead Reduction Filter H2O-F46 / 7400356 6 Months or 4,000 Gallons
Substance Average Influent NSF/ANSI
Influent
Challenge
Concentration
Percent Reduction
Requirement/Maximum
Permissible Product
Water Concentration
Average % Reduction Average Product Water
Concentration
NSF/ANSI 42 — Aesthetic Effects
Chlorine 2.01 mg/L 2.01 mg/L ± 10% ≥ 50% >94.8% 0.103 mg/L
Particulate, Class I particles
0.5 to < 1
3,666,667 particles/mL At least 10,000
particles/mL
≥ 85% 99.2% 28,017 particles/mL
NSF/ANSI 53 — Health Effects
Cyst 71,500/L Minimum 50,000/L > 99.95% 99.99% 4.88/L
Lead pH 6.5 0.151 mg/L 0.15 mg/L ± 10% mg/L 0.010 mg/L >99.7% 0.005 mg/L
Lead pH 8.5 0.16 mg/L 0.15 mg/L ± 10% mg/L 0.010 mg/L >99.2% 0.0011 mg/L
Not all water will contain contaminants listed. Testing performed under standard laboratory conditions; actual performance may