Manual

Installation Instructions
FHB-1-PEX Freezeless Wall Hydrants provide a year round
supply of outside water without the fear of pipes freezing or
bursting. Hose must be removed to allow water to drain to
prevent freezing.
Freezeless Wall Hydrants assure no-freeze operation because
the valve mechanism shuts off the water inside the building,
where it is heated. If the building will be unheated for any
length of time, then all water lines should be drained and
plumbing
fixtures winterized.
The FHB-1-PEX Freezeless Wall Hydrant features an antisiphon
vacuum breaker that protects against possible outside water
being siphoned back into the potable water supply.
A plastic siding wedge is provided to com-
pensate for lap siding installations. Slip the
wedge between the wall hydrant flange and
siding to form an attractive finish and solid
base for mounting. Secure wall hydrant
flange with two #8 or #10 oval-head wood
screws (of proper length) or with appropriate
masonry hardware.
Series FHB-1-PEX
Inlet
1
2" (15mm) PEX
Freezeless, Self Draining Wall Hydrants,
PEX End Connection
IS-FHB-1-PEX
FHB-1-PEX
Installer Please note:
A. Hose end must be installed sufficiently lower than the seat/
PEX end to allow for proper drainage.
B. Follow PEX tubing manufacturer’s crimp joining instruc-
tions.
Watts PEX end freezeless wall hydrants conform to ASTM
F1807-04 PEX end specifications.
Crimp outside diameters should fall within these dimensions
when measured with a micrometer or caliper.
SIDING WEDGE
Ring size Minimum Maximum
in mm
1
2 15 0.700" 0.715"
See back page for repair kit and service information