Owner manual

8550 Hansen Road Houston, Texas 77075 (Ph) 713.943.0688 (Fx) 713.944.9445 www.wattsacv.com
01/05
R
Classic Series
Opens at adjustable rate on pump start-up
Closes at adjustable rate on pump shut-off
Limit Switch turns pump off when valve closes
Built-in Mechanical Lift-Check Feature
prevents flow reversal
Solenoid equipped with Manual Operator
1
X
3
6
3
2
4
CLOSES VALVE
OPENS VALVE
FLOW
5
X
XX
1
Y/FC
X
Y/FC
F513-5 (Globe)
F1513-5 (Angle)
f513-5 link
1 - Main Valve (Dual Chamber w/Lift-Check)
2 - 4-Way Solenoid
3 - Check Valve
4 - Limit Switch
5 - Adjustable Opening Speed
6 - Adjustable Closing Speed
° X - Isolation Cocks (STANDARD)
° FC - Flo-Clean Strainer (OPTIONAL)
° Y - Y-Strainer (STANDARD)
° L - Dual Limit Switch
STANDARD COMPONENTS
OPTIONS and ACCESSORIES
PUMP CONTROL VALVE with
MECHANICAL CHECK FEATURE