Installation Instructions

Page 2
WARNING
!
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
If you are unsure about installing your WATTS water filter, contact
a WATTS representative or consult a professional plumber.
Discard small parts remaining after the installation.
Failure to install the system correctly voids the warranty.
Handle all components of the system with care. Do not drop,
drag or turn components upside down.
For units that are not cabinet mounted, be sure the floor under
the water filter system is clean, level and strong enough to support
the unit.
IMPORTANT
CAUTION
!
NOTICE
Overview
Thank you for your purchase of a state of the art Water
Treatment system.
Your new Certied system is equipped with premium coconut
shell Inline Granular Activated Carbon with quick connect
ttings. This system is easy to connect and can be used in
Reverse Osmosis (RO) Inline post lter, water coolers/fountains,
coffee/tea makers, refrigerators, motor homes, campers, and
other low ow applications.
Inline Granular Activated Carbon lter reduces chlorine and odor
from the water to improve taste. This system is certied for Lead
Free compliance.
System Maintenance
It is important to change lters at the recommended interval
indicated in this manual. Many contaminants are not detectable
by taste. In addition, other bad tastes and odors may become
apparent over time if lters are not replaced.
When replacing any of the lter elements, pay special attention
to any cleaning instructions. Should you have any further
questions, please call our retail customer service
at (888) 321-0500
Operational Parameters
NOTICE
Installation must comply with state and local plumbing regulations.
Contents of Under
Counter System
Please make sure all of the items listed below are contained in the
box. If any of the items are missing please contact retail customer
service at (888) 321-0500 prior to installing.
• Inline Granular Activated Carbon lter
• Parts Bag (Quick Connect Fittings- 2 Quantity)
System Diagram
A
BB
Parts List
Item Description
A Inline Granular Activated Filter
B Quick Connect Fittings
Filter and Quick connect
tting installation
Step 1 - Note direction of
water ow arrow on
lter.
Step 2 - Remove the end cap
plugs from the lter
and discard them.
Step 3 - Hand tighten tting in
clock-wise direction
as required to ensure
leak free connection.
Do not over tighten
ttings.
Step 4 - Blunt cut the tube
(tube is not supplied
with the product)
square. It is essential
that the outside
diameter of tube be
free of score marks
and that burrs and
sharp edges be
removed before inserting into tting. Now insert inlet
and outlet tubing into the quick connect ttings.
Step 5 - Follow Start up instructions
Maximum Minimum
Operating Temperature: 100°F (37.8°C) 35° F (2°C)
Operating Pressure: 100 psi (690 kPa) 25 psi (172 kPa)
pH Parameters: 10 5
Max Flow Rate: 0.5 gpm