ES-FV4-M1
Job Name
–––––––––––––––––––––––––––––––––––––––––––
Contractor
––––––––––––––––––––––––––––––––––––––––––––
Job Location
–––––––––––––––––––––––––––––––––––––––––
Approval
–––––––––––––––––––––––––––––––––––––––––––––
Engineer
–––––––––––––––––––––––––––––––––––––––––––––
Contractor’s P.O. No.
––––––––––––––––––––––––––––––––––
Approval
–––––––––––––––––––––––––––––––––––––––––––––
Representative
––––––––––––––––––––––––––––––––––––––––
Series FV-4M1
Automatic Air Vent Valves
Sizes:
1
⁄8" – 1"
Series FV-4M1 Automatic Air Vent Valves provide automatic air
venting for hot or cold water distribution systems. These vents
purge air that may be in the water system.
The vent valve utilizes a float to actuate the valve plug which is
located at the top of the valve. Once the air is displaced and the
system pressure is sustained, the valve plug seals and prevents
any water from escaping from the system.
The float vent can also operate as an anti-vacuum device since
it will permit air to enter the system when it must be drained. It
can also be installed to permit the separation and dispersal of air
while fluid is actually circulating in the system.
Features
• Body and cover are brass construction
• Air vent with silicone rubber seal
• Impurities do not usually affect function as maximum float line
of water is always lower than the valve seal
• Float is high temperature resistant polyethylene
• Suitable for use with glycol systems
• Can be disassembled for inspection and cleaning
Pressure – Temperature
Minimum working pressure: 1.45psi (10 kPa)
Maximum working pressure: 150psi (10 bar)
Temperature Range: 33˚F – 240˚F (5˚C – 116˚C)
Specifications
Air vent shall have brass body & cover and silicone rubber seal.
Float shall be constructed of high temperature resistant polyeth-
ylene and shall be for use with glycol systems. Air vent shall be
Watts Series FV-4M1.
Venting Air
Float
Silicone
Seal
Float
Collar
Spring Loaded
Lever
(Air)
Vacuum
Breaker
Diagram above shows the quantity of air vented by the “Float Vent”
according to the pressure in the system.
Vacuum
Breaker
Float
1
/8" –
1
/4"
Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with-
out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
The information contained herein is not intended to replace the full
product installation and safety information available or the experience
of a trained product installer. You are required to thoroughly read all
installation instructions and product safety information before begin-
ning the installation of this product.
NOTICE
1
/2" – 1"