Troubleshooting guide

Page 16
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVALS:
Depending on incoming feed water conditions replacement time frame may vary.
Change Time Description
6 months: Sediment Pre-lter (104017) Carbon Pre-lter (101009)
12 months Final Carbon lter (100014)
2 to 5 years R.O. Membrane (110017)
The membranes have been tested according to NSF/ANSI 58 for reduction of the substances below. The concentration of the indicated substances
in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specied
in NSF/ANSI 58. The memrbanes have been tested for the treatment of water containing pentavalent arsenic (also known as As (V), As (+5), or
arsenate) at concentrations of 0.30 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This
system is to be used on water supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been
demonstrated to contain only pentavalent arsenic. Treatment with chloramine (combined chlorine) is not sufcient to ensure complete conversion of
trivalent arsenic to pentavalent arsenic. Please see the Arsenic Facts section of the installation manual for further information.
Avg. In. Avg. Eff. % Reduction pH Pressure Max Eff. Inf. challenge Max Allowable
(mg/L) (mg/L) mg/L concentration concentration
mg/L mg/L
Arsenic (Pentavalent) 334.62 ug/L 5.039 ug/L 98.4% 50psi 19 ug/L 0.30±10% 0.010 mg/L
Barium Reduction 10.2 0.13 98.7% 7.24 50psi 0.27 10.0±10% 2.0
Cadmium Reduction 0.031 0.0001 99.7% 7.49 50psi 0.0009 0.03±10% 0005
Chromium (Hexavalent) 0.30 0.006 98.0% 7.24 50psi 0.013 0.03±10% 0.1
Chromium (Trivalent) 0.30 0.003 99.0% 7.24 50psi 0.008 0.03±10% 0.1
Copper Reduction 3.0 0.04 98.7% 7.64 50psi 0.06 3.0±10% 1.3
Cysts 222,077#/ml 10 #/ml 99.99% 50psi 58 minimum 50,000/mL N/A
Fluoride Reduction 8.0 0.33 95.9% 7.49 50psi 0.47 8.0±10% 1.5
Lead Reduction 0.15 0.004 97.3% 7.49 50psi 0.008 0.15±10% 0.0107
Radium 226/228 25pCi/L 5pCi/L 80.0% 7.24 50psi 5pCi/L 25pCiL±10% 5pCiL
Selenium 0.10 <0.001 99.0% 50psi <0.001 0.10±10% 0.05
TDS 765 24 96% 7.84 50psi 39.0 750±40mg/L 187
Turbidity 81 NTU 0.15 NTU 99.8% 50psi 0.28 NTU 11±1 NTU 0.5 NTU
Testing performed under standard laboratory conditions, actual performance may vary. Refer to owners manual for further maintenance requirements
and warranty information.
Phone: (480) 675-7995 Fax: (623) 866-5666 Email: wpmail@watts.com
GENERAL USE CONDITIONS:
1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. Do not use with
water that is microbiologically unsafe or unknown quality without adequate disinfection before and after the system.
2. Operating Temperature: Maximum: 100°F (40.5°C) Minimum: 40° (4.4°)
3. Operating Water Pressure: Maximum: 100 psi (7.0kg/cm2) Minimum: 40 psi (2.8kg/cm2)
4. pH 2 to 11
5. Hardness of more than 10 grains per gallon (170 ppm) may reduce TFM membrane life expectancy.
6. Recommend TDS (Total Dissolved Solids) not to exceed 1800 ppm.