Troubleshooting guide
Page 13
System Maintenance Continued...
Items needed:
Annual Maintenance
√ Stage 1 - Sediment Filter (part #: 104017)
√ Stage 2 & 3 - Carbon Block Filter (part #: 101009)
√ Stage 6 - Final In-line Filter (part #: 100014)
Step 1
Note:
Sanitizing of unit is recommended.
Perform steps 1 through 5 in the Six Month System Maintenance (Page 12).
Note:
If not sanitizing the system skip to step 8.
Step 3
Step 4
Step 5
Step 6
Remove the RO membranes from their housings and rest them in a clean sanitary place. (Refer
to “Membrane Replacement” section on page 14 for directions on removing the membranes).
Replace cap onto empty membrane housings and re-connect white tubing.
Step 2
Leaving the lters out, replace stage 2 and 3 empty lter housings (hand tight) onto unit.
Measure & pour either 1/2 cup of hydrogen peroxide or common household bleach into the
1st lter housing (Stage 1) and hand tighten onto unit.
With the RO faucet in the closed position turn on the incoming water supply to the system.
Wait 1 minute for the unit to pressurize. Turn on the RO faucet and let the water run for 30
seconds. Turn off the RO faucet and let the unit rest for 2 minutes. Finally, open the RO faucet
and let the water run for 5 more minutes.
Turn off the incoming water supply to the system. Keep the RO faucet open until the
storage tank is completely drained.
Open the membrane housings and re-install the RO membranes while making sure not to
kink the O-rings. (Refer to “Membrane Replacement” section on page 14 for directions on
installing the membrane). Tighten the caps back on the housings and reconnect white tubing.
Step 7
Remove lter housings Stage 1, 2 & 3 and empty of water.
Before re-installing the lter bowls back on to the system , check O-rings to make sure
they are still in place and lubricate with water soluble lubricant.
Caution:
Insert the new sediment lter (cloth like appearance) into the 1
st
lter housing which is the one
on the water inlet side (green tubing from the adapt-a-valve) of the RO system and
re-install housing.
Step 8
Insert the new Carbon Block lter (White End Caps) into the 2nd and 3rd housing and
re-install housings.
Step 9
Tip:
This is a good time to check the air pressure in your storage tank. For instructions
please see page 15.
Step 10
The nal in-line lter clipped on to the top of the reverse osmosis membrane housing.
Remove it from the holding clips and remove the compression ttings on both ends of the
lter. Install ttings on to new lter and re-connect. (Discard used nal lter after santizing)
Note:
The ow arrow on the nal lter must be pointing towards the RO faucet / away from
the RO storage tank.
Step 11
Follow Start-up procedure on page 11.










