M Series Reverse Osmosis Processor With Built-in Pre-treatment and Membrane Flush For Models: M- 450 M-1000 M-2400 M-4800 M-9600 Installation, Operation & Maintenance Manual Page 1 of 18
Before installing and/or operating Watts M-Series Reverse Osmosis system, read this manual completely. Keep this manual available for future reference. Further information is available by contacting your local Watts distributor.
TABLE OF CONTENTS Specifications Specifications Chart ……………………………… 4 Installation Membrane installation ………………………………. 5 Inlet Connection ………………………………………. 6 Permeate Line Connection …………………..……. 7 Pressure Tank Connection ……………………..…. 8 Atmospheric Storage Tank ………………………… 9 Plumb to Drain ………………………………………. 10 Operation Start Up …………………………………………………..11 Alarms …………………………………………………….12 Maintenance Quarterly Maintenance ………………………………13 Annual Maintenance ………………………………….
Specifications Complete System Packages SPECIFICATIONS DRY WEIGHT lbs. M-450 300 M-1000 310 M-2400 350 M-4800 650 M-9600 750 WET WEIGHT lbs 550 1700 1750 4000 4100 FEED WATER COLD/Temp HOT/ Temp FLOW RATE MAX.HARDNESS MAX. TDS MAX. IRON MAX. PSIG MIM. PSIG DRAIN CONNECTION FLOOR SINK MIM.
Membrane Installation Note: All Membrane Vessels are clearly marked with flow direction. Membrane “Brine Seal” is always facing the water entry to Vessel.
Inlet Connection HOT and/or COLD FEED WATER CONNECTION Hard plumb Hot and/or Cold water connections into Blending Valve using (L) Copper Pipe. Refer to table below. Valve is marked with HOT and Cold connections. Recommend installing Ball Valves just prior to the Blending Valve. NOTE: Use only Teflon tape on all threaded pipe.
Permeate Line Connection Required fittings for Bulkhead & Tank M450 ½” MPT x 3/8C . M1000 ½” MPT x 3/8C M2400 ½” MPT x ½”C M4800 ¾” MPT x ¾” Female Slip Schedule 40 PVC M9600 1” MPT x 1” Female Slip Schedule 40 PVC Ball Valve used with Pressure Tank applications.
Pressure Tank Connection Recommended tubing size From bulkhead on unit to tank . Note: Fittings are included with Systems ordered as complete packages only! M450 - M2400 Flexible poly tubing acceptable. M4800 – M9600 Schedule 80 PVC required. M-450 3/8” M-1000 3/8” M-2400 3/8” M-4800 ¾” M-9600 ¾” Note: Copper pipe is UNSUITABLE for any plumbing from RO Storage Tank! Recommended materials include: Braided Stainless Steel Tubing, Hard Stainless.
Atmospheric Storage Tank Bulkhead & Fitting Systems M-450 3/8” M-1000 3/8” M-2400 3/8” Plumb Drain Connection located on Bulkhead of RO system to floor drain, using table specifications below or appropriate air gap drain with minimum drain size of 1 1/4”. M-4800 3/4 “ Note: Refer to local plumbing codes for requirements in your area. M-9600 3/4” Note: Copper pipe is UNSUITABLE for any plumbing from RO Storage tank! Recommended materials include: Braided Stainless Steel Tubing, Hard Stainless.
Plumb to Drain Bulkhead Connection Drain Size Min.
Start Up ü Ensure power switch (located on top of control Box). 2 3 (#1) is in the OFF position. 4 ü Plug the unit into an appropriate power supply. ü If installing a pressure Tank system, open the Ball 6 Valve (#2) on the Bulkhead. 7 ü Turn the Blending Valve to coldest setting [90°]. (#3) ü Fully open the Concentrate Needle (#4) Valve by turning it counter clockwise. ü Fully close Recirculate Needle Valve (#5) by turning it clockwise.
ALARMS M-Series processors are equipped with audible alarms. 1. The Constant Tone signals lack of incoming water pressure. (-------------------------------------------------------- Constant Tone) • Check incoming feed pressure to ensure a minimum of 20 psi. • Water pressure below 20 psi will trigger alarm. Incoming feed water pressure must be raised. 2. One second intermittent beeping signals systems is in Auto –Bypass. (-- -- -- -- -- -- -- -- -- -- -- -- -- -- One second intermittent tone).
Maintenance Quarterly Preventive Maintenance for Systems with complete Pre and Post treatment. The M-Series RO processor requires quarterly preventive maintenance consisting of replacing (3) pre-filters and post Filters if supplied. 1. Pre-filters are located on left side of RO processor. 2. Post filters located on right side of RO processor unit. Quarterly preventive maintenance procedure. 1. Turn incoming feed water off while unit is running. 2.
Annual Preventive Maintenance Perform quarterly preventive maintenance. Include replacement of O-Rings. Replace RO membrane by loosen retaining clamp at top of stainless steel membrane vessel . Carefully pry loose PVC end cap from stainless steel vessel. Pull membrane from vessel using pliers i necessary and discard. Take note of location of black BRINE SEAL located approx. 1/2” from one end of membrane, so the new membrane will be installed in the proper direction.
Annual Preventive Maintenance Lubricate O-Rings on both ends of the Membrane and PVC Vessel Cap with K-Y Jelly or other water soluble lubricant. *Vaseline or other petroleum based lubricants will damage rubber o-ring and cause leaks. Insert new membrane into vessel with the Brine Seal on same position as the old one just removed. Replace PVC end cap and tighten clamp evenly.
WARRANTY WHAT YOUR WARRANTY COVERS: If any part of your Premier Water Treatment Device is defective in workmanship (excluding replacement filter elements), return the unit within 1 year of date of original purchase. PREMIER will repair or, at PREMIER’S option, replace it at no charge. HOW TO OBTAIN WARRANTY SERVICE: Contact WATTS PREMIER’S customer service department (1-800-752-5582) to obtain a Return Goods Authorization Number (RGA#). Model and Serial Number are required for obtaining an RGA #.
GLOSSARY OF TERMS Atmospheric tank: A storage container requiring additional delivery system to distribute stored water. Typically constructed of polyurethane or stainless steel. Used in situations where greater storage capacity is needed than offered by conventional pressure tanks. Auto By-Pass: A feature that allows tap water to be delivered to downstream demands in the event the RO processor is unable to meet demand.
GLOSSARY OF TERMS (Continued) Permeate: That portion of the feed water which passes through the membrane to become product water. Permeate Line: Tubing or pipe used to transport purified (RO processed) water from processor to the storage tank. Pressure tank: A water storage device using a pressurized bladder that provides delivery pressure to down stream uses. Purge: The act of flushing out.