User's Manual
INSTALLATION
For ease of installation, manufacturer recommends use of a deep wall box.
1. Disconnect power to circuit by turning circuit breaker OFF before
installation.
2. Remove existing wall plate and switch.
3. Strip existing wires 1/2” (12.7mm).
4. Connect the LINE, NEUTRAL, LOAD and GROUND supply wires to the
DRD40 fl ying leads, according to the wiring diagram below.
5. Attach the wall plate.
6. Switch the circuit breaker back ON.
INSTALL IN COMPLIANCE WITH ALL APPLICABLE
CODES & STANDARDS.
Failure to follow these instructions may cause
personal injury or equipment damage.
LOAD
LINE
Supply
Wires
Load
Wires
NEUT
Wire Legend
Load (red)
Ground
Line (blk)
Neutral (wht)
GND
CAUTION
TURN THE POWER OFF AT THE CIRCUIT BREAKER
BEFORE INSTALLING THE DIMMER.