Instruction Manual

Watlow Series PD 96 Chapter 9 Device Config Table
Parameter Name
and Description
Web Page Your
Settings
Range Default Modbus*
(Read/write and
scaling)
Output 3 - Output Source Alarm 4Set to enable Alarm 4 source.,Configuration Output 3,,No (0)Yes (1),No (0),473 (R/W)
Output 3 - Output Source Alarm 5Set to enable Alarm 5 source.,Configuration Output 3,,No (0)Yes (1),No (0),474 (R/W)
Output 3 - Output Source Alarm 6Set to enable Alarm 6 source.,Configuration Output 3,,No (0)Yes (1),No (0),475 (R/W)
Output 3 - Output Source Alarm 7Set to enable Alarm 7 source.,Configuration Output 3,,No (0)Yes (1),No (0),476 (R/W)
Output 3 - Output Source Alarm 8Set to enable Alarm 8 source.,Configuration Output 3,,No (0)Yes (1),No (0),477 (R/W)
Output 3 - Output Source Digital 3Set to enable Digital Input 3 source.,Configuration Output 3,,No (0)Yes (1),No (0),499 (R/W)
Output 3 - Output Source Digital 4Set to enable Digital Input 4 source.,Configuration Output 3,,No (0)Yes (1),No (0),500 (R/W)
Output 3 - Output LogicSelect output state in an alarm true condition.,Configuration Output 3,,Energized (0)De-energized (1),Energized
(0),478 (R/W)
Output 3 - Analog TypeSelect analog output type.,Configuration Output 3,,Voltage (0)Current (1),Voltage (0),479 (R/W)
Output 3 - mA Low ScaleSet unit value for low end of current range. This setting determines range of output.,Configuration Output 3,,0 to
20000,4000,480-481 (R/W) (/1000)
Output 3 - mA High ScaleSet unit value for high end of current range. This setting determines range of output.,Configuration Output 3,,0
to 20000,20000,482-483 (R/W) (/1000)
Output 3 - Output Source
Alarm 4
Set to enable Alarm 4 source.
Configuration Output 3 No (0)
Yes (1)
No (0) 473 (R/W)
Output 3 - Output Source
Alarm 5
Set to enable Alarm 5 source.
Configuration Output 3 No (0)
Yes (1)
No (0) 474 (R/W)
Output 3 - Output Source
Alarm 6
Set to enable Alarm 6 source.
Configuration Output 3 No (0)
Yes (1)
No (0) 475 (R/W)
Output 3 - Output Source
Alarm 7
Set to enable Alarm 7 source.
Configuration Output 3 No (0)
Yes (1)
No (0) 476 (R/W)
Output 3 - Output Source
Alarm 8
Set to enable Alarm 8 source.
Configuration Output 3 No (0)
Yes (1)
No (0) 477 (R/W)
Output 3 - Output Source
Digital 3
Set to enable Digital Input 3
source.
Configuration Output 3 No (0)
Yes (1)
No (0) 499 (R/W)
Output 3 - Output Source
Digital 4
Set to enable Digital Input 4
source.
Configuration Output 3 No (0)
Yes (1)
No (0) 500 (R/W)
Output 3 - Output Logic
Select output state in an
alarm true condition.
Configuration Output 3 Energized (0)
De-energized (1)
Energized (0) 478 (R/W)
Output 3 - Analog Type
Select analog output type.
Configuration Output 3 Voltage (0)
Current (1)
Voltage (0) 479 (R/W)
Output 3 - Current Low Scale
Set unit value for low end of
current range. This setting
determines range of output.
Configuration Output 3 0 to 20000 units 4000 480-481 (R/W)
(/1000)
Output 3 - Current High Scale
Set unit value for high end of
current range. This setting
determines range of output.
Configuration Output 3 0 to 20000 units 20000 482-483 (R/W)
(/1000)