Instruction Manual
Name and Descri
p
tion
Web Pa
ge
Ran
g
e
(
Scalin
g)
Iterations Default EIP Decimal
(
Hex
)
Modbus EIP Data T
y
p
e
A
cces
s
Silencing
Select whether to allow the operator to disable the
alarm output before the process value returns to
normal.
Alarm {1 to 8}
Configuration
No (0)
Yes (1)
Alarm 1
Alarm 2
Alarm 3
Alarm 4
Alarm 5
Alarm 6
Alarm 7
Alarm 8
No (0)
105/1/6 (69/1/6)
105/2/6 (69/2/6)
105/3/6 (69/3/6)
105/4/6 (69/4/6)
105/5/6 (69/5/6)
105/6/6 (69/6/6)
105/7/6 (69/7/6)
105/8/6 (69/8/6)
537
551
565
579
593
607
621
635
UINT R/W
Blocking
Select to block this alarm until the process value
enters the normal range after turning the power on
or after a set point change.
Alarm {1 to 8}
Configuration
Off (0)
Set Point Change (1)
Power On (2)
Set Point Change and
Power On (3)
Alarm 1
Alarm 2
Alarm 3
Alarm 4
Alarm 5
Alarm 6
Alarm 7
Alarm 8
Off (0)
105/1/5 (69/1/5)
105/2/5 (69/2/5)
105/3/5 (69/3/5)
105/4/5 (69/4/5)
105/5/5 (69/5/5)
105/6/5 (69/6/5)
105/7/5 (69/7/5)
105/8/5 (69/8/5)
536
550
564
578
592
606
620
634
UINT R/W
Device Configuration > Network > Email
SMTP Server IP Resolution
Specify the method to determine the SMTP server.
Device Configuration
Network
Email
Server Name (0)
Fixed Address (1)
Server Name (0) Web page only Web page only R/W
SMTP Server Name
Specify the SMTP server name.
Device Configuration
Network
Email
0 Web page only Web page only R/W
SMTP Server Fixed Address
Specify the SMTP server's fixed IP address.
Device Configuration
Network
Email
-2,147,483,647 to
2,147,483,647
-1,062,731,775 Web page only Web page only R/W
Source Email Address
Specify the return source of submitted email. This
source is included in sent emails
.
Device Configuration
Network
Email
0 Web page only Web page only R/W
Email Recipient {1 to 4}
Specify an email recipient. Up to four mail boxes
ma
y
receive an email.
Device Configuration
Network
Email
0 Web page only Web page only R/W
Device Configuration > Data Logging > Settings
Data Logging
Enable or disable data lo
gg
in
g.
Datalog Configuration
No (0)
Yes (1)
No (0) 107/1/20 (6B/1/14) 1209 UINT R/W
Parameters to Data Log: Process Value {1 to 4}
Specify whether to include the corresponding
process value in the datalog.
Datalog Configuration
No (0)
Yes (1)
Process Value 1
Process Value 2
Process Value 3
Process Value 4
No (0)
107/1/2 (6B/1/2)
107/1/3 (6B/1/3)
107/1/4 (6B/1/4)
107/1/5 (6B/1/5)
1191
1192
1193
1194
UINT R/W
Parameters to Data Log: Working Set Point {1
or 2}
Specify to whether to include the corresponding
set
p
oint in the datalo
g.
Datalog Configuration
No (0)
Yes (1)
Set Point 1
Set Point 2
No (0)
107/1/6 (6B/1/6)
107/1/6 (6B/1/6)
1195
1196
UINT R/W
Parameters to Data Log: Loop Power {1 or 2}
Specify whether to include the corresponding
power output in the datalog.
Datalog Configuration
No (0)
Yes (1)
Loop 1
Loop 2
No (0)
107/1/10 (6B/1/A)
107/1/11 (6B/1/B)
1199
1200
UINT R/W
Parameters to Data Log: {Digital or CT} Input
{3 or 4} Status
Specify whether to include the corresponding
di
g
ital in
p
ut status in the datalo
g.
Datalog Configuration
No (0)
Yes (1)
Digital or CT
Input 3
Digital or CT
Input 4
No (0)
107/1/8 (6B/1/8)
107/1/9 (6B/1/9)
1197
1198
UINT R/W
SERIES PD with EtherNet/IP
Addressing Information (rev c)
181










