Output Logic Operator
Select the logic operation to determine the event
output status.
Output {1 to 4}
Configuration
And (0)
Or (1)
Output 1
Output 2
Output 3
Output 4
And (0)
104/1/7 (68/1/7)
104/2/7 (68/2/7)
104/3/7 (68/3/7)
104/4/7 (68/4/7)
399
439
469
509
UINT R/W
Output Active State
Select the output state when an alarm condition is
true.
Output {1 to 4}
Configuration
Energized (0)
De-Energized (1)
Output 1
Output 2
Output 3
Output 4
Energized (0)
104/1/18 (68/1/12)
104/2/18 (68/2/12)
104/3/18 (68/3/12)
104/4/18 (68/4/12)
408
448
478
518
UINT R/W
Output State
Indicates the state of the output.
Inactive (0)
Active (1)
Output 1
Output 2
Output 3
Output 4
Inactive (0)
104/1/5 (68/1/5)
104/2/5 (68/2/5)
104/3/5 (68/3/5)
104/4/5 (68/4/5)
397
437
467
507
UINT R
Device Configuration > Alarms > Alarm {1 to 8}
Alarm Type
Select the type of alarm. A process alarm
responds when the temperature crosses a fixed
value. A deviation alarm responds when the
termperature deviates from the controlled setpoint
by the Alarm Deviation Set Point.
Alarm {1 to 8}
Configuration
Off (0)
Low Process (1)
High Process (2)
Low Deviation (3)
High Deviation (4)
Low CT (5)
High CT (6)
Alarm 1
Alarm 2
Alarm 3
Alarm 4
Alarm 5
Alarm 6
Alarm 7
Alarm 8
Off (0)
105/1/1 (69/1/1)
105/2/1 (69/2/1)
105/3/1 (69/3/1)
105/4/1 (69/4/1)
105/5/1 (69/5/1)
105/6/1 (69/6/1)
105/7/1 (69/7/1)
105/8/1 (69/8/1)
531
545
559
573
587
601
615
629
UINT R/W
Process Alarm Source
Select which process value the alarm will monitor.
Alarm {1 to 8}
Configuration
Process Value 1 (0)
Process Value 2 (1)
Alarm 1
Alarm 2
Alarm 3
Alarm 4
Alarm 5
Alarm 6
Alarm 7
Alarm 8
Process Value 1
(0)
105/1/2 (69/1/2)
105/2/2 (69/2/2)
105/3/2 (69/3/2)
105/4/2 (69/4/2)
105/5/2 (69/5/2)
105/6/2 (69/6/2)
105/7/2 (69/7/2)
105/8/2 (69/8/2)
532
546
560
574
588
602
616
630
UNIT R/W
Process Alarm Set Point
Set the temperature or process value that will
trigger the alarm.
Alarm {1 to 8}
Configuration
-30,000,000 to 30,000,000
(/1000)
Alarm 1
Alarm 2
Alarm 3
Alarm 4
Alarm 5
Alarm 6
Alarm 7
Alarm 8
0
101/1/49 (65/1/31)
101/1/55 (65/1/37)
101/1/61 (65/1/3D)
101/1/67 (65/1/43)
101/1/73 (65/1/49)
101/1/79 (65/1/4F)
101/1/85 (65/1/55)
101/1/91 (65/1/5B)
106-107
119-120
132-133
145-146
158-159
171-172
184-185
197-198
DINT R/W
Deviation From Loop
Select which set point the alarm will monitor.
Alarm {1 to 8}
Configuration
Loop 1 (0)
Loop 2 (1)
Alarm 1
Alarm 2
Alarm 3
Alarm 4
Alarm 5
Alarm 6
Alarm 7
Alarm 8
Loop 1 (0)
105/1/3 (69/1/3)
105/2/3 (69/2/3)
105/3/3 (69/3/3)
105/4/3 (69/4/3)
105/5/3 (69/5/3)
105/6/3 (69/6/3)
105/7/3 (69/7/3)
105/8/3 (69/8/3)
533
547
561
575
589
603
617
631
UINT R/W
Deviation Alarm Set Point
Set the deviation from the set point that will trigger
an alarm.
Alarm {1 to 8}
Configuration
-30,000,000 to 30,000,000
(/1000)
Alarm 1
Alarm 2
Alarm 3
Alarm 4
Alarm 5
Alarm 6
Alarm 7
Alarm 8
1
101/1/48 (65/1/30)
101/1/54 (65/1/36)
101/1/60 (65/1/3C)
101/1/66 (65/1/42)
101/1/72 (65/1/48)
101/1/78 (65/1/4E)
101/1/84 (65/1/54)
101/1/90 (65/1/5A)
104-105
117-118
130-131
143-144
156-157
169-170
182-183
195-196
DINT R/W