User Manual
→ [Diag] Diagnostics Menu
µ
[Fcty] Factory Menu Prompt
↓
?
µ
[dAtE] Factory Ship Date
↓ ?
µ
[SOFt] Software Revision
↓ [Sn--]
µ
[----] Serial Number
↓ ?
µ
[AMb] Ambient Temperature
↓ ?
µ
[`gnd] Ground A/D Count
↓ ?
µ
[`rEF] Ambient A/D count
↓ ?
µ
[cnt1] Input 1 A/D count
↓ ?
µ
[cnt2] Input 2 A/D count
↓ ?
µ
[ity1] Input 1 Module Type
↓ ?
µ
[ity2] Input 2 Module Type
↓ ?
µ
[Oty1] Output 1 Module Type
↓
?
µ
[Oty2] Output 2 Module Type
↓ ?
µ
[Oty3] Output 3 Module Type
↓ ?
µ
[Oty4] Output 4 Module Type
↓ ?
µ
[diSP] Test Displays
↓ ?
← µ [tout] Test Outputs
6.8 WATLOW Series 998 User’s Manual
Factory Menus, Chapter 6
Factory-Diagnostics
Reaching the Diagnostics Menu
❷ Use the Up-arrow > key to step from
the Panel Lockout Menu [PLOC] to the
Diagnostics Menu [diag].
❶ Press the Up-arrow > and Down-arrow
< keys together and hold until the
[`SEt] prompt appears in the lower dis-
play. Press and hold again until the [Fcty]
prompt appears in the lower display.
Panel
Lockout
Menu
p. 6.2
Diagnostics
Menu
p. 6.8
Calibration
Menu
p. 6.14
[PLOC]
[Fcty]
[diAg]
[Fcty]
[`CAL]
[Fcty]
>
>
>
❸ Press the Mode key µ to step through
the prompts.
❹ Press the Up-arrow key > or the
Down-arrow key < to select one of the
prompt values.
[`OFF]
[tout]
[out1]
[tout]
[out4]
[tout]
…
>
>>
>
Figure 6.8 -
The Diagnostics Menu.
NOTE:
In the Diagnostics Menu
only the values of [dISP]
and [tout] can be
changed.
Enter your settings,
from the controller’s
upper display.