A.18 Appendix Watlow Series 97
Electromechanical Relay
Form C contact configuration
Minimum load current 10mA @ 5VÎ (dc)
Rated resistive and inductive loads: 2A @ 250VÅ (ac) or
30VÎ (dc) maximum
Electrical life 100,000 cycles at rated current
For resistive loads only, must use RC suppression for
inductive loads
Retransmit
Range selectable: 0-20mA, 4-20mA, 0-5VÎ (dc),
1-5VÎ (dc), 0-10VÎ (dc)
0 to 10VÎ (dc) voltage output into a 1,000 minimum load
resistance
0 to 20mA current output into an 800 maximum load
resistance
Resolution:
dc ranges = 2.5mV nominal
mA ranges = 5µA nominal
Calibration accuracy:
dc ranges = ±15mV
mA ranges = ±30µA
Temperature stability 100ppm/°C
Communications
EIA/TIA-485, EIA/TIA-232
Opto-isolated
Modbus
RTU protocol
1200, 2400, 4800, 9600, 19200 baud rates
32 maximum units can be connected (With additional 485
repeater hardware, up to 247 units may be connected)
Accuracy
Input ranges
Type J: 32 to 1382°F or 0 to 750°C
Type K: -328 to 2282°F or -200 to1250°C
Type T: -328 to 662°F or -200 to 350°C
Type N: 32 to 2282°F or 0 to1250°C
Type E: -328 to 1470°F or -200 to 900°C
Type C(W5): 32 to 4200°F or 0 to2315°C
Type D(W3): 32 to 4200°F or 0 to2315°C
Type PTII: 32 to 2540°F or 0 to1393°C
Type R: 32 to 2642°F or 0 to1450°C
Type S: 32 to 2642°F or 0 to1450°C
Type B: 1598 to 3092°F or 870 to1700°C
DIN: -328 to 1472°F or -200 to 800°C
JIS: -328 to 1166°F or -200 to 630°C
Thermocouple Inputs
Calibration accuracy ±0.1% of span ±1°C at standard
conditions
Exceptions:
Type T; 0.12% of span for -200°C to -50°C,
Types R and S; 0.15% of span for 0°C to 100°C
Types B; 0.24% of span for 870°C to 1700°C
Accuracy span: 540°C/1000°F minimum
Temperature stability: ±0.1 degree per degree change in
ambient
Specifications
(2195)
Controller
Microprocessor-based, user selectable control modes
Input sample period; Single input 10Hz (100 msec), dual input
5Hz (200 msec) digital filter adjustable
Display update; 2Hz (500 msec), time filter adjustable
Input/Output/Communication isolation
Displayed in °C or °F
Operator Interface
Dual 4-digit LED displays: upper 10.2 mm (0.4 in), lower 6.2
mm (0.244 in)
Advance, Up Arrow, Down Arrow, Reset tactile keys
Standard Conditions For Specifications
Ambient temperature 25°C/77°F ±3°C, rated line voltage, 50 to
60Hz, 0 to 90% RH non-condensing,
15 minute warm-up
Universal Input 1
Thermocouple
Type J, K, T, N, C (W5), E, PTII, D (W3), B, R, S thermocouple
types
>20M input impedance
Maximum 20 source resistance
30mA open detection bias
RTD
2- or 3-wire platinum, 100
DIN and JIS curves
Whole or tenth degree indication
150µA nominal RTD excitation currrent
Input 2
Event Input
Contact or voltage
20K input impedance
Voltage input: event high state 3 to 36VÎ (dc),
event low state 0 to 2VÎ (dc)
Resistance/contact input: event high state > 23k, event low
state 0 to 2k
Output Types
Open Collector/Switched DC
Open collector configuration:
Maximum voltage 42VÎ (dc)
Maximum current 200mA
Maximum on resistance 1.1
Maximum offstate leakage current 100µA
Switched dc configuration:
Switched dc supply voltage 22 to 28VÎ (dc)
dc supply current limited to 30mA
Solid-state Relay
Optically isolated
Zero cross switched
Without contact suppression
Minimum load current 0.5mA rms
Maximum current 0.5A rms at 20 to 280VÅ (ac)
Maximum offstate leakage current 10µA rms
For resistive loads only, must use RC suppression for
inductive loads