Owner manual

Series 102
Users Manual
On-off Temperature
Controller
1241 Bundy Boulevard, P.O. Box 5580, Winona, Minnesota USA 55987-5580
Phone: +1 (507) 454-5300, Fax: +1 (507) 452-4507, Internet: http://www.watlow.com
The Watlow Series 102 is a 1/16 DIN, on-off
temperature controller with a thermocouple or RTD sensor
input.
The compact size of the controller allows more flexibility
in applications where space is a problem. The Series 102 has
a standard integral setpot and front panel LED output
status indicator.
(1915)
Control Mode
On-off
Nominal switching hysteresis, typically 3°F (1.7°C)
Operator Interface
Sealed membrane front panel
LED indication of output status
Dial scale calibrated to compensate for sensor non-linearities
Integral set point
Dual temperature scale (°F and °C)
Input
Thermocouple or platinum RTD available
Thermocouple with automatic cold junction compensation
Thermocouple may be isolated or grounded
Thermocouple and RTD break protection de-energizes output
2- or 3-wire RTD input, 100, 500 or 1000 @ 0°C calibrated for
0.003850/ °C curve, factory selectable
Output
Electromechanical relay, 3A, Form C, SPDT: 3A @ 240VÅ, 3A @
28VÎ (dc), resistive, 240V~ 275 VA pilot duty rated
Solid-state relay, Form A, 0.5A @ 24VÅ min., 264VÅ max., opto-
isolated, zero cross switching
Switched dc configuration; switched dc supply voltage 3 to 32VÎ
(dc) into a minimum 500 load
Accuracy
Adjustable Set Point
Calibration accuracy: ±1% of span, at 77°F ±5°F (25°C ± 3°C)
ambient and rated line voltage ± 1%
Set point accuracy: ±3% of dial scale
Accuracy span: 1000°F (540°C) minimum
Fixed Set Point
Calibration accuracy: ±10°F/±6°C of setting, at 77°F ±5°F (25°C
±3°C) ambient and rated line voltage ±1%
Temperature Stability
Thermocouple: Typically 5µV/°F ambient (9µV/°C ambient) input
referenced
RTD: Typically 0.2°F/°F ambient (0.2°C/°C ambient)
Voltage Stability
±0.01% of span (min span of 1000°F or 540°C) per % of rated line
voltage
Agency Approvals
CE: EN61010 - Safety
EN61326 - Industrial Immunity, Class B Emissions
Installation Category 2, Pollution Degree 2
873, File #E43684
to C22.2 No. 24, File #E43684
Approved for use in commercial cooking applications
Terminals
Screw clamp terminal: 12- to 26-gauge wire
Power
120V~, +10%/-15%, 50/60 Hz
230V~ to 240~, +10%/-15%, 50/60 Hz
10VA maximum power
Operating Environment
32 to 131°F (0 to 55°C)
0 to 90% RH, non-condensing
Storage temperature: -4 to 185°F (-20 to 85°C)
Dimensions
Height: 2.1 in (55 mm)
Width: 2.1 in (55 mm)
Depth: 4.0 in (102 mm)
Behind panel: 3.50 in (89 mm)
Front panel: 0.5 in (13 mm)
Weight
0.7 lb (0.3kg)
UL
®
is a registered trademark of Underwriters Laboratories, Inc.
Note: Specifications subject to change without notice.
Specifications
General Description
$5.00 Made in the U.S.A.
Printed on Recycled Paper
10% Postconsumer Waste
0600-0004-0006 Rev C
August 2000
Supersedes: 0600-0036-0002 Rev B
Registered Company