WATLOW Series 982 User’s Manual 5.3
Operation Menus, Chapter 5
System Prompts
When you are in the Operations menus the Series 982 displays the menu
selection ( [`SYS], [`Pid] or [Prog] ) in the upper display and [OPEr] in
the lower display.
The Up-arrow > or Down-arrow key < selects another menu. Press the
Mode key µ to display the first prompt in the lower display and its value
in the upper display. Use the Up-arrow > and Down-arrow < keys to
change the value in the upper display. The new value will not take effect
until after a five-second delay or until you press the Mode key µ.
Event Input 1 Status
Indicates whether the event input 1 circuit is open or closed. This is
a read-only prompt.
[Ei1S] This prompt appears only if [`Ei1] (Global Menu) is set to some-
thing other than [``no] .
Default
[OpEn] [CLOS]
[Ei1S] [Ei1S]
Event Input 2 Status
Indicates whether the event input 2 circuit is open or closed. This is
a read-only prompt.
[Ei2S] This prompt appears only on controllers equipped with event input
2 hardware (98__-_5__-____) and with [`Ei2] (Global Menu) set to some-
thing other than [``no] .
Default
[OpEn] [CLOS]
[Ei2S] [Ei2S]
˜
NOTE:
Decimal points may
not always be in the
position specified
depending on the
setting in the
Decimal 1 [dEC1]
parameter in the
Input Menu.
[Ei1S]
[Ei2S]