User`s manual

Watlow EZ-ZONE™ Communications 59 Chapter 6 Operations Page
Parameter name
Description
Modbus
(less
40,001
offset)
read/
write
CIP
class
instance
attribute
read/
write
Range Default Data
Type
EZ-ZONE™
PM Int.*
EZ-ZONE™
PM PID*
EZ-ZONE™
PM Limt*
Monitor
Ambient Temperature, Input 2
View the ambient temperature.
446 r 104
2
4 r
-1,999.000 to 9,999.000°F or
units
-1,128.000 to 5,537.000°C
floating
point
XXX
Monitor
Bumpless Set Point
View the set point that will take effect if a
bumpless transfer occurs.
2178 r 107
1
10 r
-1,999.000 to 9,999.000°F or
units
-1,128.000 to 5,537.000°C
floating
point
XX
Monitor
Control Loop Output Power
View the output power.
1908 r 151
1
15 r
-100.0 to 100.0 floating
point
XX
Monitor
Event 1 Status
View the status of event 1.
1328 r 110
1
5 r
Inactive (41)
Active (5)
integer X X X
Monitor
Event 2 Status
View the status of event 2.
1348 r 110
2
5r
Inactive (41)
Active (5)
integer X X X
Monitor
EZ Key Status
View the status of event 3.
1368 r 110
3
5 r
Inactive (41)
Active (5)
integer X X X
Monitor
Limit State
View the limit state.
690 r 112
1
6 r
Off (62)
None (61)
Limit High (51)
Limit Low (52)
Error (28)
integer X X
Monitor
Ramp Active Set Point
View the current ramp set point.
2190 r 107
1
16 r
-1,999.000 to 9,999.000°F or
units
-1,128.000 to 5,537.000°C
floating
point
XX
Monitor
Ramp Target Set Point
View the target ramp set point.
2198 r 107
1
20 r
-1,999.000 to 9,999.000°F or
units
-1,128.000 to 5,537.000°C
floating
point
Loop Menu
Loop
Remote Enable
Switch control to the remote set point.
2200
r/w
107
1
21 r/w
No (59)
Yes (106)
No
integer X
Loop
Remote Set Point Type
Select how the remote set point will be de-
termined.
2202
r/w
107
1
22 r/w
Auto (closed loop) (10)
Manual (open loop) (54)
Auto
integer X
Loop
Control Mode
Select the method that the controller will
use to control.
1880
r/w
151
1
1 r/w
Off (62)
Auto (closed loop) (10)
Manual (open loop) (54)
Auto
integer X X
Loop
Autotune Set Point
Set the set point that the autotune will use,
as a percentage of the current set point.
1918
r/w
151
1
20 r/w
50.0 to 200.0% 90.0
floating
point
XX
Integers are unsigned, 16-bit values. Floating point values are IEEE 754 32-bit floating point values.
The default Modbus order is Low Word-High Word. The order can be changed in the Communications Menu.
The default serial data format is: 9,600 baud; 8 data bits; no parity; 1 stop bit.
NOTE: Avoid continuous writes within loops. Excessive writes to the EEPROM will cause premature EEPROM failure. The EEPROM is
rated for 1,000,000 writes.
Underlined parameters are not accessable using a remote user's interface (RUI) or the controller's front panel. They can only be ac-
cessed using communications.
*Some of the parameters are not functional in some configurations of each model. Check the user's manual for information.
Int.
PID
Lmt.