User manual
Procedure
#
Step
See ‘Open and Close the Folder Cover’
on page 39
Open the folder cover.1
‘Illustration’ on page 109 shows the
correct position for the shuttle assem-
bly. The screw ‘A’ must align with
the white gear ‘B’.
If the shuttle assembly does not move
to the correct position, push the pick-
up fingers away from each other by
2-3mm and try again. Repeat if nec-
essary.
See ‘Illustration’ on page 109.
Push the shuttle-assembly to the
end.
2
If the message does not clear, check
that the shuttle assembly is in the
correct position. Repeat Step 2 if
necessary.
Wait until the error message
SHUTTLE NOT PARKED is
cleared from the screen.
3
Close the folder cover.4
Result
The error message ‘MANUALLY PARK SHUTTLE’ is cleared from the screen. The
shuttle axis re-references and the message Shuttle axis moving is displayed.
When the message list is clear, you can continue operation
Chapter 5 - Error Conditions, Problems and Solutions110
Manually park the Shuttle