snap into the “tripped” position and the spa should stop operating. Reset the sub-panel GFCI breaker by completely flipping the
breaker switch down, into the off position. Then, flip the breaker switch up, into the on position. Power should be restored and the
spa should resume operation. If the breaker does not perform in this manner, there may be an electrical malfunction and with it,
the possibility of an electric shock. Disconnect the power until the problem has been corrected.
Da n g e r : ri s k o f e l e c t r i c s h o c k
•Installatleast5feet(1.5m)fromallmetalsurfaces.Aspamaybeinstalledwithin5feetofametalsurfaceifeachmetalsurfaceis
permanently connected by a minimum No. 8 AWG (8.42 mm
2
) solid copper conductor attached to the wire ground connector on
the terminal box that is provided for this purpose if in accordance with National Electrical Code ANSI/NMFPA70-1993.
•Donotpermitanyelectricalappliances,suchasalight,telephone,radio,ortelevisionwithin5feet(1.5m)ofaspa.Failureto
maintain a safe distance may result in death, or serious personal injury due to electrocution, if the appliance should fall into the
spa.
•Installyourspaissuchawaythatdrainageisawayfromtheelectricalcompartmentandfromallelectricalcomponents.
do:
•Besureyourspaisconnectedtothepowersupplycorrectly-usealicensedcontractor.
•Disconnectthespafromthepowersupplybeforedrainingthespaorservicingtheelectricalcomponents.
•TesttheGroundFaultCircuitInterrupter(s)beforeeachuse.
don’t:
•Usethespawiththeequipmentcompartmentdoorremoved.
•Placeelectricalapplianceswithin5feet(1.5m)ofthespa.
•Useanextensioncordtoconnectthespatoitspowersource.Thecordmaynotbeproperlygroundedandtheconnectionis
a shock hazard. An extension cord may cause a voltage drop, which will cause overheating of the jet pump motor and motor
damage.
•Attempttoopentheelectricalcontrolbox.Therearenouserserviceablepartsinside.