Specifications

64
64
(continued on next page)

pR o b l e m pR o b a b l e C a U s e s so l U t I o n s
Entire spa is inoperative
• Powerfailure/notpluggedin
• GFCItripped
• Heaterhigh-limitthermostattrippe
• Checkpowersource
• ResetGFCI;callforserviceifitwillnotreset
• Disconnectpowerforatleastthirtysecondstoresetheaterhighlimit.
If it will not reset, check for clogged filters. If tripping continues, call for
service.
Spa jets and heat off, light
operates
(Display reads _ . _ . _ . _
)
• Pressureswitchisopenwhenjetsareon
and should be closed.
• Checkforcloggedfilter.Thepressureswitchwillresetwhentheflow
of water through the heater has been restored. Call for service if the
pressure switch trips frequently
(Display reads
_ _ _ _
)
Pressure switch senses flow through heater
even though the jet pump is off
Contact an Authorized Service Technician
READY icon flashes
• ControlSensoropenorshorted • ContactanAuthorizedServiceTechnician
Jets weak or surging
• Spawaterleveltoolow
• Filtersclogged/Jetintakescreensclogged
• Jetnozzlesclosed/Airvalveclosed
• Addwater
• Cleanfilters/Cleanjetintakescreens
• Openjetnozzles/Openairvalve
Light inoperative
• Spalockactivated
• Lightwiringorassemblyisfaulty
• Deactivatespalock
• Replacelightassembly
.
Display reads - - - -
(Entire spa inoperative)
• Heaterhigh-limitthermostattripped • Disconnectpowertothespaforatleastthirtysecondstoresettheheater
high-limit. If tripping continues, clean the filter, then if tripping still
occurs, call for service.
.
Set water temperature
significantly different from
display temperature
• SystemControls • ContactanAuthorizedServiceTechnician
_ _ _ _
_ . _ . _ . _