Specifications
60
6060606060
pH control. If the TA is too high, the pH is difficult to adjust. If the TA is too low, the pH will be difficult to hold at the proper level.
The desired range of TA in spa water is 40 to 120 ppm.
VI. seRVIce InFoRMatIon
Your Solana
®
Spa has been designed to provide years of trouble-free use. As with any appliance, problems may occasionally occur
that require the expertise of a qualified service person. Though such simple repairs as resetting a GFCI switch or breaker, High Limit
Thermostat, or Pressure Switch or replacing a light bulb may not require a service call, they may indicate that a more serious condition
exists. These conditions may require an experienced service person. Before calling for service, please refer to the Troubleshooting Guide.
NOTE: Always retain your original sales receipt for future reference.
GFCI AND HIGH-LIMIT THERMOSTAT
If your spa fails to operate at any time, the following items should be checked:
Check the power supply to the spa.1.
Check the GFCI (located at the end of the cord in standard models or in the electrical sub-panel in 30 or 50 amp converted models) 2.
and see if it has tripped. If a GFCI has tripped, reset it. If it will not reset, this may be an indication of a ground fault (short circuit)
within the electrical components. Contact an Authorized Service Technician for a complete diagnosis.
If upon checking the GFCI you find it has not tripped, check the house breaker panel and ensure the main breaker for the electrical
3.
circuit supplying the spa has not tripped. If it has, this is an indication that either the circuit was overloaded or a ground fault
exists between the breaker panel and the spa receptacle. Contact a qualified electrician.
If, upon checking the main house breaker, you find no failures, the heater high-limit thermostat should be checked. Tripping of the 4.
heater hight-limit thermostat is normally a result of one or a combination of any of these problems: 10 blockage within the system
plumbing, 2) switch malfunction in the heater circuit, or 3) the low speed mode of the jet pump is not functioning.
If the heater high-limit has tripped, the control panel will read ----. Reset the heater high-limit by allowing the water to cool and 5.
disconnecting power to the spa for at least thirty seconds. If the heater hight-limit continues to trip, contact an Authorized Service
Technician for a complete diagnosis.