Specifications

2
222
av o i d i n g t h e ri s k o f el e c t r o c u t i o n
Da n g e r : ri s k o f e l e c t r o c u t i o n
•Connectonlytoagroundedsource.
•Donotburythepowercord.Aburiedpowercordmayresultindeathorseriouspersonalinjuryduetoelectrocutionifdirect
burial-type cable is not used, or if improper digging occurs.
•Agroundterminal(pressurewireconnector)isprovidedonthecontrolboxinsidetheunittopermitconnectionofaminimum
No. 8 AWG (8.4 mm
2
) solid copper bonding conductor between this point and any metal equipment, metal water pipe, metal
enclosures of electrical equipment, or conduit within five feet (1.5 m) of the unit as needed to comply with local requirements.
•Donotoperatetheaudiomaincontrolswhileinsidethespa(ifspaisequippedwithanaudiocomponent).
•Donotconnectanyauxiliarycomponents(forexample,cableadditionalspeakers,headphones,additionalaudiocomponents)to
the audio system unless approved by Watkins Manufacturing Corporation .
•Donotselfserviceaudiocomponentbyopeningorremovingcoverasthismayexposedangerousvoltageorotherriskofinjury.
Refer all servicing to qualified service personnel.
•DonotattachanexternalantennaetoaspaaudiosystemunlessinstalledbyalicensedelectricianinaccordancewithArticle810
of the National Electric Code, ANSI/NFPA 70.
Wa r n i n g :
•Toreducetheriskofelectricalshock,replaceadamagedcordimmediately.Failuretodosomayresultindeathorserious
personal injury due to electrocution.
•YourspaisprovidedwithaGroundFaultCircuitInterrupterforuserandequipmentprotection.Toensureproperoperationof
this important safety device, test according to the following instructions per electrical configuration.
Cord-Connected 115 Volt, 20 Amp Models: The GFCI is located at the end of the power cord. Before each use, with the unit
operating, push the TEST button. The unit should stop operating. Push the RESET button. The spa should now return to normal
operation. If the interrupter does not perform in this manner, there may be an electrical malfunction and with it, the possibility of
an electric shock. Disconnect the power until the problem has been corrected.
Hard-Wired 115 Volt, 30 Amp Models: The GFCI breaker, located inside the sub-panel, supplies all of the power to the spa.
Before each use, open the sub-panel and press the TEST button located on the sub-panel GFCI breaker. The breaker should