Specifications
27272727
Under normal conditions, the heater and low-speed cycle will run 2-4 times per day for approximately 20 minutes per cycle. If the
ambient temperature falls below 20°F (-7° C), the heater may not be able to raise the spa water to the desired temperature, and the
heater and low-speed cycle will run continuously, resulting in substantially higher operating costs.
fi l t e r cy c l e
When the spa is first powered up the automatic filter cycle will wait 10 minutes before starting. Your spa will
automatically turn the filter cycle on for 60 minutes on low speed. The second filter cycle will activate for 30
minutes, 12 hours later. The filter cycle icon, F1 or F2, will be displayed in the control panel.
Note: The optional FreshWater
®
III ozone system only works during the filter cycles.
The filtration is suspended when the ambient temperature remains high for more than 3 hours. In this scenario,
the heater will not cycle on because the spa water temperature does not cool. If the heater does not cycle on, the low-speed jet pump
will not automatically engage. This is very critical when using the FreshWaterAg+
®
silver ion purifier, which relies on circulation to
disperse silver ions throughout the spa. When engaged, the circulation switch will activate the low-speed jet pump for a 1.0 hour filter
cycle. If, during the filter cycle, a user enters the spa and turns on the high-speed jet pump, the filter cycle will pause. When the high-
speed pump is shut off, the filter cycle will resume.
The filter cycle begins when the timer is activated. Thereafter, the filter cycle will repeat for the same time every 12 hours. The only
exception occurs in the event of a power failure. If power is disconnected from the spa while the circulation timer is activated, the
circulation cycle will reset and engage when power is reapplied. Therefore, if you have activated the timer at 8 am, the low speed jet
pump will be activated from 8 am to 9:30. The cycle will repeat again after 12 hours. However, if a power failure occurs at 10 am, and
power is reapplied at 10:30 am, the cycle will reset and the low speed jet pump will activate from 10:30 am to 12:00 pm.
to a c t i v a t e t h e fi l t e r t i m e r :
To modify the length of either filter cycle:
A. Press and hold the SET button for approximately three seconds.
B. Press the LIGHT button to select filter cycle 1 or 2 (F1 or F2 will be displayed).
C. Using the Temp Up (
▲
) or the Temp Down (
▼
) button, adjust the value as desired, from 0 to 6 hours.
D. Programming will then be saved, 10 seconds after last button is pressed. The display will then revert back to temperature display.
The filter cycle will activate the jet pump on low-speed for the entire cycle. When activated, the filter cycle Icon on the display is turned
on. If the temperature exceeds the set point by three degrees F for more than three hours, the system will cancel the FILTER cycle and