Specifications
18
NOTE:
- Jumpers are located in top right
corner of Control Box labeled P4
“Config Jumpers”
- To Change from fahrenheit to
celsius remove jumper on JP2.
- Verify Red Internal Power Jumper is
connected at P40 (B) to P24 (B).
2 Position Power Jumper
must be removed on the
Terminal Block to operate
230 VAC Spa Models
Power Jumper Position
See Wiring
Illustration
230 VAC Wiring
(50A Converted)
When Converting to 50 A
Install Jumper on JP1
Main Service
Electrical Panel
230VAC, 50 Amp
2-Pole Circuit
CIircuit Breaker
(Non GFCI)
WIRING ILLUSTRATION
OPTIONAL 50A/230V SUBPANEL CONVERSION CONNECTION
230 VAC, 40A, 60HZ, CONVERTED MODELS
Less Than 100 FT.
#8 AWG White, Neutral
#10 AWG Green, Ground
#8 AWG Black, L1
#8 AWG Red, L1
Sub-Panel
with GFCI
Breakers
More than 5 feet
the Sub-Panel must be
within sight of the spa
Do Not Exceed 50 Feet
Control Box
N, Neutral, #8 AWG White
L1, Hot, #8 AWG Black
Ground, #10 AWG Green
L2, Hot, #8 AWG Red