Specifications
5. Inside the control panel, locate the terminal block (TB-1).
6. Remove existing power cord.
7. Connect the #10 AWG, BLACK wire from the sub-panel 30 amp GFCI breaker [terminal L1] to TB-1 terminal L1.
8. Connect the #10 AWG, WHITE wire from the sub-panel 30 amp GFCI breaker [terminal N, load neutral] to TB-1 terminal N.
9. Connect the #10 AWG, GREEN wire from the sub-panel GROUND bar to TB-1 terminal GROUND.
The GFCI breaker inside the sub-panel supplies all of the power to the spa. Before each use, open the sub-panel and press the TEST
button located on the sub-panel GFCI breaker. The breaker should snap into the “tripped” position and the spa should stop operating.
Reset the sub-panel GFCI breaker by completely pressing the breaker switch down, into the OFF position. Then, flip the breaker switch
up, into the ON position. Power should be restored and the spa should resume operation.
If the GFCI breaker fails to operate in this manner, it is an indication of an electrical malfunction and the possibility of an electric shock.
Disconnect the power until the fault has been identified and corrected.
IMPORTANT: Should you ever find the need to move or relocate your Solana
®
spa, it is essential that you understand and apply
these installation requirements. Your Solana spa has been carefully engineered to provide maximum safety against electric shock.
Remember, connecting the spa to an improperly wired circuit will negate many of its safety features.
co n v e r t e d 230 vo l t , 50 am P co n f i g u r a t i o n
co n v e r s i o n i n s t r u c t i o n s
NOTE: An Authorized Solana
®
Spa Technician must perform the conversion.
1. Disconnect power to the spa and access the control box.
2. Locate the program jumpers (JP1 - JP8) at the top right of the control box.
3. Using a pair of needle nose pliers, carefully remove the parked (spare) jumper.
4. Attach parked jumper to JP1 as on next page.
A licensed electrician must install the sub-panel (available from your Solana Spa Dealer) to supply
power to the spa. The sub-panel must be placed in sight of the spa, at a minimum distance of 5 feet (1.5 m) away.