Specifications

30 am p s u b -p a n e l w i ring i n s t r u c t i o n s
NOTE: The sub-panel must be placed within 100 feet of the main electrical service panel, and between 5 and 50 feet (1.5 and 15 meters)
away from the spa. Refer to the wiring diagram below.
1. Connect the #10 AWG, WHITE [NEUTRAL] wire from the main electrical service panel to the sub-panel NEUTRAL bar.
2. Connect the #10 AWG, GREEN [GROUND] wire from the main electrical service panel to the sub-panel GROUND bar.
3. Connect the #10 AWG, BLACK [L1] wire from the main electrical service panel to the sub-panel [terminal L1].
4. Check the connections internal to the sub-panel and be sure that a pigtail wire exists between the neutral bar and the 30 amp
breaker. NEVER remove the pigtail wires!
16161616
115VAC, 30
Amp Single Pole
Circuit Breaker
(Non GFCI)
Main Service
Electrical Panel
Sub-Panel
with GFCI
Breakers
More than 5 feet
the Sub-Panel must be
within sight of the spa
Do Not Exceed 50 Feet
Control Box
N, Neutral, #10AWG White
L1, Hot, #10AWG Black
Ground, #10AWG Green
Less Than 100 FT.
#10 AWG White, Neutral
#10 AWG Green, Ground
#10 AWG Black, L1
WIRING ILLUSTRATION
PERMANENTLY CONNECTED FOR
115 VAC, 24A, 60HZ, CONVERTED MODELS