Installation guide
WaterWorks ......... AUTOMATIC WATER CONDITIONER
PREMIER DEMAND TIMER FEATURES, SETTINGS, AND SERVICE, continued
service: MANUAL ADVANCE REGENERATION CHECK
This check verifies proper operation of the valve
motor, brine tank fill, brine draw, regeneration flow
rates, and other timer -valve functions. First, make
the initial checks, and the manual initiated diag-
nostics.
NOTE: The face plate display must show a steady
time (not flashing)•
1. Press the TOUCH - HOLD button and hold in for
3 seconds. RECHARGE NOW begins to flash as the
softener enters the fill cycle of regeneration. Re-
move the brinewell cover and, using a flashlight, ob-
serve fill water entering the brine tank.
0 If water does not enter the tank, look for an ob-
structed nozzle, venturi, fill flow plug, brine tubing,
or brine valve riser pipe.
2. After observing fill, press the TOUCH - HOLD but-
ton to move the softener into brining. A slow flow of
water to the drain will begin. Verify brine draw from
the brine tank by shining a flashlight into the brine-
well and observing a noticeable drop in the liquid
level.
...other inner valve defect (rotor seal, rotor & disc,
wave washer, etc.).
4. Press TOUCH - HOLD to move the softener into
fast rinse. Again look for a fast drain flow. Allow the
softener to rinse for a few minutes to flush out any
brine that may remain in the resin tank from the brin-
ing cycle test.
5. To return the softener to service, press TOUCH -
HOLD.
WIRING SCHEMATIC
BACK OF
TIMER
TRANSFORMER
24V
J
NOTE: Be sure a satt bridge is not preventing water
with salt contact.
$ If the softener does not draw brine...
...nozzle and/or venturi dirty or defective.
...nozzle and venturi not seated properly on gasket.
...restricted drain (check drain fitting and hose).
•..defective nozzle and venturi seal.