Installation guide
WaterWorks ......... AUTOMATIC WATER CONDITIONER
PREMIER DEMAND TIMER FEATURES, SETTINGS, AND SERVICE, continued
service: MANUAL INITIATED
1. To enter diagnostics, press
and hold the DATA button until
the display appears as shown
here. The dY and number, in the
top part of the display, is days
since the last recharge. See (A)
and (B) following, explaining the
bottom portion of the display.
NOTE: If the softener is in the
middle of a regeneration, the top
part of the display shows the
cycle of regeneration, and min-
utes of the cycle remaining. If 2
cycle names are flashing, the
valve is in transition between the
cycles.
ELECTRONICS DIAGNOSTIC
switch turbine
count
valve minutes of cycle
position remaining
_MOTOR
SITI_ON_ SENSOR
PO HOUSING
TURBINE
VALVE
OUTLET_
TURBINE
SUPPORT &
SHAFT
(A) The 3 digits, under WATER MANAGEMENT
SYSTEM, indicate water meter operation as follows:
$ 000 (steady) = soft water not in use...no flow
through the meter.
-- OPEN A NEARBY SOFT WATER FAUCET --
i 000 to 140 (continual) = repeats display for each
gallon of water passing through the meter.
If you don't get a reading in the display, with faucet
open, pull the sensor from the valve outlet port. Pass
a small magnet back and forth in front of the sensor.
You should get a reading in the display. If you get a
reading, unhook the in and out plumbing and check
the turbine for binding.
(B) This display'segment (--0"_-), in the following
table, indicates an open POSITION switch. The oth-
er indicates a closed switch. Use the TOUCH -
HOLD button to manually advance the valve into
each cycle and check correct switch operation.
CORRECT
SWITCH
DISPLAYS VALVE CYCLE STATUS
_._=.........,,.._ Valve in service, fill, brining,
backwash or fast rinse position,
Valve rotating from one position
to another,
2. Press the DATA button again.
This diagnostic display, shows the
total number of recharges (top)
since the timer was connected to
electrical power.
The number of days since the timer was connected
to electrical power, is shown in the bottom part of the
display. If over 1999 days, a (x 10) indicator shows,
meaning you must multiply the number shown times
10.
3. Press DATA once again to return the present time
to the display.
23