Installation guide

WaterWorks TM......... AUTOMATIC WATERCONDITIONER
PREMIER DEMAND TIMER FEATURES, SETTINGS, AND SERVICE, continued
feature: OPTIONAL RECHARGE CONTROLS ............................................
Sometimes, a manually started regeneration (re- ... You did not refill the storage tank with salt before
charge) may be desired, or needed. Two examples it was all gone.
are:
... You have used more water than usual (house
guests, extra washing, etc.) and you may run out of
soft water before the next regeneration.
Use 1 of the following features to start a regenera-
tion immediately, or at the next preset regeneration
start time.
RECHARGE NOW
Press and hold in the TOUCH - HOLD button until
RECHARGE NOW starts to flash in the time display
area. The softener begins an immediate regenera-
tion, and when over in about 2 hours, you will have
a new supply of soft water. Once started, you cannot
cancel this regeneration.
RECHARGE TONIGHT
Touch (do not hold) the TOUCH - HOLD button, and
RECHARGE TONIGHT flashes in the time display
area. A regeneration will occur at the next preset re-
generation start time. If you decide to cancel this re-
generation, before # has started, touch the same
button once more.
VACATION NOTE .............................................................................
This demand water softener regenerates only when water is used and softening capacity must be restored.
For this reason, the softener will not regenerate while you are away from home for extended periods.
feature: PROGRAM MEMORY ..........................................................
If electrical power to the softener is interrupted, the
time display is blank, but the timer keeps correct
time for about 24 hours. When power is restored,
you have to reset the present time only if the display
is flashing. All other settings are maintained and
never require resetting unless a change is desired.
If the time is flashing after a long power outage, the
softener continues to work as it should to provide
you with soft water. However, regenerations may oc-
cur at the wrong time of day until you reset the timer
to the correct time of day, page 11.
19