Installation guide

WaterWorks ...... AUTOMATIC WATER CONDITIONER
INSTALLATION
9. ADD WATER AND SALT TO THE BRINE
TANK:
Remove the salt storage area cover. Add about
3 gallons of water into the tank. Do not add into the
brinewell.
Fill the tank with NUGGET, PELLET or coarse
SOLAR water softener salt. Do not use rock, block,
granulated, and ice cream making salts, or salt with
iron removing additives. Also see page 16. Salt
storage capacity is 200 Ibs or more.
Note: If the softener is installed in a humid basement
or other damp area, it is better to fill the tank with less
salt, more frequently (see salt bridging in the mainte-
nance section). Eighty to 100 Ibs of salt will last for
several months, depending on water hardness and
family size.
STEPS, continued
10. CONNECT TO ELECTRICAL POWER:
The softener works on 24 volt, 60 Hz electric pow-
er. The included transformer changes standard 120
volt AC house power to 24 volts. Plug the trans-
former into a 120 volt outlet only. Be sure the out-
let is always "live" so it can not be switched off by
mistake.
Fasten the 2 power cable lugs to the 2 screws on the
transformer, and tighten the screws. Then, plug the
transformer into the electrical outlet.
11. PROGRAM THE PREMIER DEMAND TIMER,
below:
PROGRAMMING THE PREMIER DEMAND TIMER
. TOUCH-HOLD button
WATER CONDI T I_
0,s,_/ J ,, 0o°oo
WaterWorks TM
DATA button
TIMER SETTINGS REQUIRED...upon installation, and after an extended power outage (see Program
Memory, page 19).
NOTES:
WHEN THE TRANSFORMER IS PLUGGED INTO THE ELECTRICAL OUTLET (STEP 10, ABOVE),
12"00AM (flashing), and PRESENT TIME show in the upper display area. Program the timer as instructed
on page 11. If A- - - is flashing, please see Model Code setting on page 21.
continued
10