WaterWorks _ Premier Demand with high-flow 1" valve AUTOMATIC WATER CON DITION ER Model WS 2000 Installation Operation Maintenance Repair Parts IF YOU HAVE QUESTIONS WHEN INSTALLING, OPERATING AND MAINTAINING YOUR CONDITIONER, AND WHEN SETTING THE TIMER. o. CALL TOLL FREE 1-800-86 Manufactured WATER by EcoWater Systems, Inc. PO BOX 64420, ST. PAUL, MN 55164 Part No.
WaterWorks TM..... • AUTOMATIC WATER CONDITIONER IIIIIII I WaterWorks I RESIDENTIAL IIIII IIII lllll WATER SOFTENER FULL ONE YEAR WARRANTY ON WATER '111 II I IIIIIII Jl WARRANTY SOFTENER For one year from the date of purchase, when this water softener is installed and maintained in accordance with our instructions, Sears will repair, free of charge, defects in material or workmanship in this water softener.
WaterWorks ...... AUTOMATIC UNPACKING The softener is shipped in 1 carton. assembled at the factory, except installation. WATER CONDITIONER / INSPECTION It is completely as required at shipping cartons. Small parts, needed to install the softener, are on a skin-packed cardboard piece. To avoid loss of the Be sure to check the entire softener for any shipping damage or parts loss. Also note any damage to the small parts, keep them on the skin-pack ready to use them.
WaterWorks TM...... AUTOMATIC WATER CONDITIONER SPECIFICATIONS / DIMENSIONS MODEL WS 2000 RATED CAPACITY See Rating Decal, Located On The Softener AMOUNT OF HIGH CAPACITY RESIN (Ibs / cuft) 52 / 1.0 9x40 RESIN TANK NOMINAL SIZE (in., dia x height) SERVICE FLOW RATE (gpm) See Rating Decal 110 WATERSUPPLYMAXIMUM HARDNESS (gpg)_ 8 WATERSUPPLYMAX. CLEAR WATERIRON (ppm)_ 20 - 125 WATERPRESSURE LIMITS (min. / max.
WaterWorks. ..... AUTOMATIC WATER CONDITIONER BEFORE STARTING • • WHERE TO INSTALL Place the softener THE • SOFTENER as close as possible pressure tank (well system) water). INSTALLATION to the Put the softener in a place water damage is least likely to occur if a leak develops. The manufacturer will not repair or pay for water damage. or water meter (city Place the softener as close as possible to a floor drain, or other acceptable drain point (laundry tub, sump, standpipe, etc.).
WaterWorks TYPICAL soft water _ ...... AUTOMATIC SOLDERED COPPER WATER CONDITIONER or CPVC INSTALLATIONS CROSS - OVER Use if water supply flows from the left. Include single or 3 - valve bypass. _ hard water vHAATR_R- W I _ _ _ E_TER FROM J| SOFTENER [ OUTLET hard water to outside faucets SOFT II TO SOFTENER V INLET I Note: To install with threaded plumbing, buy 1" adaptors, either sweat solder or compression, to connect to the 1" copper tubes.
WaterWorks ...... AUTOMATIC INSTALLATION 1. INSTALL BYPASS VALVE and/or COPPER WATER CONDITIONER STEPS FIGURE TUBES: _ [] NOTE: Before installing the copper tubes or bypass valve, be sure the turbine and support are firmly In place, in the valve outlet. Blow into the valve port and observe the turbine for free rotation.
WaterWorks ...... AUTOMATIC INSTALLATION 4. PLUMB STEPS, IN AND OUT PIPES TO AND FROM SOFTENER Turn (SEE PAGE 6): off the open faucets house to relieve water supply pressure • BE SURE RAW, HARD WATER TO THE VALVE INLET PORT. • valve continued • Use pipe joint compound threads. on all external pipe • Support inlet and outlet plumbing in some manner (use pipe hangers) to keep the weight off of the valve fittings.
WaterWorks ...... AUTOMATIC WATER CONDITIONER INSTALLATION STEPS, continued Also provide an air gap of at least 1-1/2" between the end of the hose and the drain point. An air gap prevents possible siphoning of sewer water, into the softener, if the sewer should "back-up". 8. • If raising the drain hose overhead is required to get to the drain point, do not raise higher than 8' above the floor. Elevating the hose may cause a back-pressure that could reduce brine draw during regenerations.
WaterWorks ...... AUTOMATIC INSTALLATION 9. STEPS, continued 10. ADD WATER AND SALT TO THE BRINE TANK: CONNECT TO ELECTRICAL POWER: • The softener works on 24 volt, 60 Hz electric power. The included transformer changes standard 120 volt AC house power to 24 volts. Plug the transformer into a 120 volt outlet only. Be sure the outlet is always "live" so it can not be switched off by mistake. • Remove the salt storage area cover. Add about 3 gallons of water into the tank.
WaterWorks TM...... AUTOMATIC WATER CONDITIONER PROGRAMMING THE PREMIER DEMAND TIMER, continued • A "beeper" sounds while pressing buttons for timer programming. One beep signals a change in the timer display. Repeated beeps means the timer will not accept a change from the button or arrow you have pressed, and you should use another. • To program • the timer, you will use the SET button. SET PRESENT NOTE: TIME OF DAY ................................................
WaterWorks ...... AUTOMATIC SANITIZING WATER CONDITIONER PROCEDURES Care is taken at the factory to keep your water softener clean and sanitary. Materials used to make the softener will not infect or contaminate your water bleach (CIorox, Linco, Bo Peep, White Sail, Eagle, etc.,) into the brinewell. Refer to figure 3, page 9. supply, and will not cause bacteria to form or grow. However, during shipping, storage, installing and operating, bacteria could get into the softener.
WaterWorks ...... AUTOMATIC WATER CONDITIONER WATER AND WATER CONDITIONING WATER, continued Municipal water supplies come from surface reservoirs, such as lakes and riv- reduced ers, or from underground reservoirs. Usually, municipalities chlorinate the water to make it safe to drink. Sediment is removed by filtration. Tastes and odors are reduced or eliminated. The water is conditioned Underground reservoirs provide our private water supplies.
WaterWorks ...... AUTOMATIC WATER AND WATER CONDITIONING, ACIDITYor acid water is caused by carbon dioxide, hydrogen sulfide, and sometimes industrial wastes. It is corrosive heaters, and also damage diaphragms, WATER CONDITIONER pH reading, the greater the acidity. A neutralizer filter or a chemical feed pump are usually recommended to treat acid water. to plumbing, plumbing fixtures, water other water using appliances. In can and cause premature failure of seals, etc., in water handling equipment.
WaterWorks ......
WaterWorks ...... AUTOMATIC WATER CONDITIONER GENERAL CHECKING Brine THE (salt dissolved SALT WATER SOFTENER STORAGE in water) LEVEL, is needed AND for each WITH SALT: Check the salt level BREAKING water softener see page 10) ...... PELLET or coarse SOLAR • •lm..= salts are NOTE: Water softening salt with iron removing additives: Some salts have an additive to help the softener handle iron in the water supply.
WaterWorks ...... AUTOMATIC GENERAL CLEANING THE NOZZLE A clean nozzle and venturi WATER SOFTENER AND VENTURI WATER CONDITIONER MAINTENANCE, ASSEMBLY continued ..................................... is needed for the soft- ener to work right, This small unit makes the suction to move brine from the salt storage area to the resin tank during regeneration. If the nozzle and venturi becomes plugged with sand, silt, dirt, etc., the softener will not work and you will get hard water.
WaterWorks PREMIER ......... AUTOMATIC DEMAND TIMER FEATURES, WATER CONDITIONER SETTINGS, NOTE: SEE PAGES 10 and 11 TO SET THE TIM ER TO TH E CORRECT NESS NUMBER. NORMAL TIMER DISPLAY OPERATION, With scan This play OTHER DATA DISPLAYS (remaining) - This is .. #,J#.we regeneration start time, then changes to RECHARGE NOW, which flashes until the regeneration is over. The display also shows the current cycle in the regeneration process.
WaterWorks PREMIER feature: charge) are: DEMAND OPTIONAL Sometimes, TM......... AUTOMATIC WATER CONDITIONER RECHARGE a manually started may be desired, ... You have used TIMER CONTROLS regeneration or needed. more water FEATURES, than SETTINGS, (re- ... You did not refill the storage Two examples usual (house Use 1 of the following features to start a regeneration immediately, or at the next preset regeneration start time. RECHARGE NOTE .............................................
WaterWorks ......... AUTOMATIC WATER CONDITIONER PREMIER DEMAND TIMER FEATURES, SETTINGS, AND SERVICE, setting: REGENERATION (STARTING) TIME, MAXIMUM DAYS BETWEEN AND HEAVY DUTY BACKWASH ........................................................ continued REGENERATIONS, NOTE: Each of these settings has a factory set default value. The defaults are: Regeneration 2:00AM; Maximum days between regenerations - 0 (display shows dY-); Heavy duty backwash start time - OFF.
WaterWorks ......... AUTOMATIC WATER CONDITIONER PREMIER DEMAND setting: MODEL NOTE: The model set default values. code should never most installations. CODE, TIMER FEATURES, SETTINGS, 12 OR 24 HOUR CLOCK, AND GALLONS continued OR LITERS MEASURE code is factory set at assembly and testing. The hour clock and water measure have factory The defaults are: 12 or 24 hour clock - 12; Gallons or liters measure - gallons.
WaterWorks PREMIER feature / service: ......... AUTOMATIC DEMAND TIMER AUTOMATIC FEATURES, ELECTRONIC SETTINGS, AND SERVICE, continued DIAGNOSTICS The timer computer has a self-diagnostic function for the electrical system (except input power and water meter). The computer monitors the electronic components and circuits for correct operation.
WaterWorks PREMIER service: ......... AUTOMATIC DEMAND MANUAL TIMER INITIATED FEATURES, ELECTRONICS WATER CONDITIONER SETTINGS, NOTE: If the softener is in the continued DIAGNOSTIC 1. To enter diagnostics, press and hold the DATA button until the display appears as shown here. The dY and number, in the top part of the display, is days since the last recharge. See (A) and (B) following, explaining the bottom portion of the display.
WaterWorks PREMIER ......... DEMAND service: MANUAL ADVANCE AUTOMATIC TIMER FEATURES, REGENERATION checks, and the manual initiated AND SERVICE, ...other inner valve defect wave washer, etc.). 4. Press TOUCH diag- continued (rotor seal, rotor & disc, - HOLD to move the softener into fast rinse. Again look for a fast drain flow. Allow the softener to rinse for a few minutes to flush out any brine that may remain in the resin tank from the brining cycle test.
WaterWorks .........
WaterWorks TM......
WaterWorks TM...... AUTOMATIC WATER CONDITIONER I REPAIR PARTS - SOFTENER KEY NO. PART NO. DESCRIPTION KEY I NO. I OF PART ASSEMBLY PART NO.
WaterWorks ...... AUTOMATIC WATER CONDITIONER REPAIR PARTS 1 VALVE ASSEMBLY 45 _ 2 4 46 __ 3 5 flow plug assembly__._ I_.
WaterWorks T. ...... AUTOMATIC WATER CONDITIONER REPAIR PARTS - VALVE ASSEMBLY KEY NO. PART NUMBER Screw, #6-20 x 7/8" (2 req.) 31 7214969 7171200 Motor (incl. 2 ea. of Key No. 1) Motor Plate 32 1202600 Nozzle & Venturi Assy. (incl. Key Nos. 31, and 33 through 41) Nut - Ferrule 0900857 Screw, #6-20 x 3/8" (3 req.) 33 7095030 Cone Screen 34 1148800 Flow Plug, .3 gpm 35 7148532 36 7O82582 Aspirator (Nozz.Nent.