WaterWorks Demand AUTOMATIC WATER CONDITIONER Model WS 1000 Installation Operation Maintenance Repair Parts IF YOU HAVE QUESTIONS WHEN INSTALLING, OPERATING AND MAINTAINING YOUR CONDITIONER, AND WHEN SETTING THE TIMER... CALL TOLL FREE 1-800-86 Manufactured by EcoWater WATER Systems, Inc. PO BOX 64420, ST. PAUL, MN 55164 Part No.
WaterWorks TM...... AUTOMATIC WATER CONDITIONER I WaterWorks I III RESIDENTIAL WATER SOFTENER FULL ONE YEAR WARRANTY ON WATER WARRANTY SOFTENER For one year from the date of purchase, when this water softener is installed and maintained in accordance with our instructions, Sears will repair, free of charge, defects in material or workmanship in this water softener.
WaterWorks ..... . AUTOMATIC WATER CONDITIONER UNPACKING / INSPECTION The softener is completely assembled at the factory, except as required at installation, and is shipped in 1 master carton. shipping Small parts, needed to install the softener, are on a skin-packed cardboard piece. To avoid loss of the small parts, keep them on the skin-pack until you are ready to use them. Be sure to check the entire softener for any shipping damage or parts loss. Also note any damage to the TABLE cartons.
WaterWorks ...... AUTOMATIC WATER CONDITIONER SPECIFICATIONS / DIMENSIONS MODEL WS 1000 RATED CAPACITY See Rating Decal, Located On The Softener 4O / ,77 AMOUNT OF HIGH CAPACITYRESIN (Ibs ! cuft) 8x40 RESIN TANK NOMINAL SIZE (in., dia x height) SERVICEFLOW RATE (gpm) See Rating WATERSUPPLYMAXIMUM HARDNESS (gpg)® 7O WATERSUPPLYMAX. CLEAR WATERIRON (ppm)® 5 Decal 20 - 125 WATERPRESSURELIMITS (rain. / max.
WaterWorks ....... AUTOMATIC BEFORE STARTING WHERE TO INSTALL WATER CONDITIONER INSTALLATION THE SOFTENER • Place the softener as close as possible to the pressure tank (well system) or water meter (city water). Put the softener in a place water damage is least likely to occur if a leak develops. The manufacturer will not repair or pay for water damage.
WaterWorks TM....... AUTOMATIC WATER CONDITIONER TYPICAL INSTALLATION ILLUSTRATION (BRINE TANK NOT SHOWN) SOLDERED COPPER, SOFT WATER []... TO INCLUDED VALVE AT SOFTENER []... HARD WATER TO OR CPVC _.,_," OUTSIDEFAUCETS 1 BYPASS l j straight connector (2) with softener * included 3/4" pipe and fittings_ TO OPTIONAL INSTALLATION ADAPTORS AT SOFTENER, USING 3-VALVE BYPASS nut (2) * in..
WaterWorks ....... AUTOMATIC WATER CONDITIONER INSTALLATION STEPS 1. INSTALL BYPASS VALVE, OR OPTIONAL INLET-OUTLET FIGURE 1 ADAPTORS: [] # / NOTE: On Demand turbine timer models, be valve sure the turbine and "/ ]///z_ I outlet support are firmly in r_/lq t _ __L (remove place, in the valve u 41 i---" -I plastic outlet.
WaterWorks TM..... ,. AUTOMATIC WATER CONDITIONER INSTALLATION STEPS, IMPORTANT: If you will use the grounding clamps and wire in step 7 on page 9, put the clamps on the copper tubes before soldering. continued back-pressure regenerations. that could reduce CONNECTING brine draw during A RIGID VALVE DRAIN TUBE • When turning threaded pipe fittings onto plastic fittings, use care not to cross-thread.
WaterWorks ....... AUTOMATIC INSTALLATION 7'. INSTALL GROUNDING WIRE (IF NEEDED): CLAMPS STEPS, continued valve, pausing several to pressurize slowly. AND times to allow the softener E. After about 3 minutes, open a HOTwater faucet for 1 minute, or until all air is expelled, then close. • To maintain electrical ground continuity in the house cold water piping, install the included ground clamps as shown. Be sure the pipes are clean, under the clamps, to assure good contact.
WaterWorks .... .. AUTOMATIC WATER CONDITIONER PROGRAMMING THE DEMAND TIMER / display / TOUCH-HOLD button up button ------- down button -------WATER I_ TIMER SETTINGS REQUIRED...upon gram Memory, page 17). SELECT CONDITIONER installation, and after an extended button power outage (see Pro- NOTES: • WHEN THE TRANSFORMER IS PLUGGED INTO THE ELECTRICAL OUTLET (STEP 10, PAGE 9), • 12"00AM (flashing), and PRESENT TIME show in the display area. Program the timer as instructed below.
WaterWorks ...... AUTOMATIC WATER CONDITIONER PROGRAMMING • SET WATER HARDNESS THE DEMAND NUMBER • SET REGENERATION number continued ...continued NOTE: Each press of a button changes the display by 1 between 1 and 25. Above 25, the display changes 5 at atime ... 25, 30, 35, etc. Holding a button in changes the numbers twice each second. See the specified maximum hardness, page 4. 2. When your water hardness SELECT to set.
WaterWorks ...... AUTOMATIC WATER CONDITIONER WATER AND WATER CONDITIONING WATER ....................................................................... Man's very existence depends on water. It is 1 of the basic commodities of life. Water is best as nature Municipal nated. The water is conditioned to comply with certain specifications. However, hardness minerals, tastes and odors are not always reduced to the most desirable levels. sphere.
WaterWorks ...... AUTOMATIC WATER CONDITIONER WATER AND WATER CONDITIONING, continued water• In some instances, treatment may improve colloidal iron water, but always CONSULT A QUALIFIED WATER CHEMISTRY LAB before attempting to treat it. Colloidal iron water usually has a yellow appearance when drawn• After standing for several hours, the color persists and the iron does not settle, but remains suspended in the water. heaters, and other water using appliances.
WaterWorks ..... . AUTOMATIC WATER CONDITIONER WATER FLOW THROUGH SOFTENER SOFT WATER SERVICE soft water OUT FILL hard water IN soft water OUT salt storage tank not shown} hard water IN s_tstorage tank brine valve brine valve \ resin tank resin bed fill water BRINING / BRINE RINSE hard water bypass OUT • hard water IN BACKWASH hard water bypass OUT t n FAST RINSE hard water IN ! > drain resin bed lifted and expanded brine va_ brine 14 soft water OUT hardwater IN
WaterWorks ...... AUTOMATIC GENERAL CHECKING WATER SOFTENER THE SALT STORAGE TO REFILL pure. NUGGET, the salt before you refill it. Without salt, you will soon have hard water. salts only, at least 99.5% A SALT BRIDGE .......... PELLET or coarse SOLAR salts are NOTE: WATER SOFTENING SALT WITH IRON REMOVING ADDITIVES: Some salts have an additive to help the softener handle iron in the water supply.
WaterWorks ...... AUTOMATIC WATER CONDITIONER GENERAL WATER SOFTENER MAINTENANCE, continued CLEANING THE NOZZLE AND VENTURI ASSEMBLY .............................. A clean nozzle and venturi is needed for the softener to work right. This small unit makes the suction to move brine from the salt storage area to the resin tank during regeneration. If it becomes plugged with sand, silt, dirt, etc., the softener will not work and you will get hard water.
WaterWorks ...... AUTOMATIC DEMAND TIMER FEATURES, NOTE: SEE PAGES 10 AND 11 TO SET THE TIMER NESS NUMBER, AND RECHARGE START TIME. NORMAL OPERATION, During normal operation, # OPTIONAL Sometimes, a manually i = = = w i a = a CHARGE regeneration features # • may be desired, ... You have used more water than usual (house guests, extra washing, before the next regeneration. Use 1 of the following time.
WaterWorks ...... AUTOMATIC WATER CONDITIONER DEMAND TIMER FEATURES, AND SERVICE, ERROR Err01 POSSIBLE DEFECT I Err02 CODE I DISPLAYED Err03 wiringharness, or connectionto switch i valve defectcausing hightorque continued I Err 05 Err04 positionswitch 0 motorinoperative timer (PWA) TO REMOVE AN ERROR CODE: (1) unplug transformer (2) correct defect (3) plug transformer in (4) Wait for at least 6 minutes.
WaterWorks ...... AUTOMATIC WATER CONDITIONER DEMAND TIMER FEATURES, If you don't get a reading in the display, with faucet open, pull the sensor from the valve outlet port. Pass a small magnet back and forth in front of the sensor• You should get a reading in the display. If you get a reading, unhook the in and out plumbing and check the turbine for binding. AND SERVICE, button to manualty advance the valve into each cycle and check correct switch operation. CORRECT SWITCH DISPLAYS C.
WaterWorks ...... AUTOMATIC DEMAND TIMER FEATURES, the brine tank by shining a flashlight into the brinewell and observing a noticeable drop in the liquid level. If water system WIRING drain hose brine draw. cause may 4. Press TOUCH back pressure, stopping - HOLD to move the softener 5. To return the softener to service, press TOUCH HOLD. is low, an elevated SCHEMATIC BACK OF FACEPLATE TIMER TRANSFORMER 120V_ 124V rn _) into fast rinse. Again look for a fast drain flow.
WaterWorks ...... AUTOMATIC WATER CONDITIONER WATER FLOW THROUGH SERVICECYCLE VALVE FILL CYCLE valve cam position switch venturi rotor & disc from Valve Inlet (hard water) .top distributor To Valve Outlet (soft water) fill flow plug from Valve Inlet (hard water) fill water (soft) top distributor resin tank resin tank To Valve Outlet € (soft water) tf_ r :;n bottom distributor _..._.
WaterWorks ...... AUTOMATIC WATER CONDITIONER REPAIR PARTS - SOFTENER ASSEMBLY 20 l 3O 24 31-.
WaterWorks ,M ...... AUTOMATIC WATER CONDITIONER I I REPAIR PARTS - SOFTENER KEY NO. PART NO. 1 7207718 2 I ASSEMBLY KEY NO. PART NO. Hose Clamp (2) 21 7178626 Rim 7207726 Ground Wire 22 7155115 Brinewell Cover 3 7176292 Clamp Section (2) 23 7082150 Wing Nut, 1/4-20 4 7088033 C_amp Retainer (2) 24 710O819 BrineweU 5 7112963 O-ring Seal Kit 25 7155034 Screw, 1/4-20 Nylon Repl.
WaterWorks ...... AUTOMATIC WATER CONDITIONER REPAIR PARTS - VALVE ASSEMBLY IDENTIFICATION NUMBER OUTSIDE DIA. 18 .37 1-EP .295 HVDC .295 ACTUAL SIZES (excludingcenter hole) CENTER HOLE DIA. ,138 @ 0501228 7092615 7097252 27 30 \\43 44 j 26 52 AVAILABLE OPTION for installing softener withoutincludedbypass vane 19 20 21 24
WaterWorks TM...... AUTOMATIC WATER CONDITIONER REPAIR PARTS - VALVE ASSEMBLY KEY NO. PART NO. 1 7070412 2 KEY NO. PART NO. Screw, #4-24 x 1-1/8" 27 -- O-ring Seal, 3-3/8" x 3-5/8" _7117816 Spacer 28 -- O-ring Seal, 3/4" x 15/18" 3 7030713 Switch 29 -- O-ring Seal, 7/16" x 5/8" 4 7077472 Expansion Pin 30 7129716 Seal Kit - Includes Key Nos.