WaterWorks TM Undersink Reverse Osmosis HOME DRINKING WATER SYSTEM Model RO 2000 Installation Operation Maintenance Repair Parts IF YOU HAVE QUESTIONS WHEN INSTALLING, OPERATING AND MAINTAINING YOUR REVERSE OSMOSIS SYSTEM... CALL TOLL FREE 1-800-86 Manufactured WATER by EcoWater Systems, Inc, PO BOX 64420, System Tested and Certified to ANSI/NSF Standard 58. See performance data sheet for details, ST. PAUL, MN 55164 Part No.
- TABLE OF CONTENTS Safety - Guides ................................................ 2-3 What Your Home Drinking Water System Will Do ..................... Things To Check Before You Start To Install ....................... 3 4-5 How To Install Your Home Drinking Water System ................. How Your Home Drinking Water System Works .................. Care Of Your Home Drinking Water System ..................... 5-11 11-12 13-16 Dimensions And Specifications ...................................
- SAFETY GUIDES house water pressure is over the maximum, install a pressure reducing valve in the water supply to the Home Drinking Water System. DO NOT USE THE SYSTEM ON MICROBIOLOGICALLY UNSAFE WATER, OR WATER OF UNKNOWN QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE OR AFTER THE SYSTEM. Systems certified for cyst reduction be used on disinfected water that contain filterable cysts. Do not install the Home Drinking Water System outside, or in extreme hot or cold temperatures.
- THINGS TO CHECK BEFORE YOU START TO INSTALL • PARTS IN THE SHIPPING CARTON -- Unpack I ELECTRONIC FAUCET BASE the carton carefully so needed parts are not discarded by mistake. Included are: DRAIN ADAPTER _ _ WATER _,/_1 (_ _ _,,_ RO ,I ASSEMBLY _b')_tl _ --. _ £ SADDLE VALVE t SUPPLY .t _ FAUCET ASSEMBLY BATTERY _ WITH HOLDER BATTERIES (4) • WATER SUPPLY -- The cold water your Home Drinking Water System must certain chemical limits (see page 17).
- THINGS TO CHECK BEFORE YOU START TO INSTALL REMOTE LOCATION -- You can install the RO assembly or water supply saddle valve in another place away from the RO faucet (please see page • REPLACING ANOTHER RO SYSTEM -- We suggest you remove all parts of another RO system, and use everything included with your new RO system. 2O).
- HOW TO INSTALL YOUR HOME DRINKING STEP 1 -- INSTALL THE COLD WATER SUPPLY WATER SYSTEM - SADDLE VALVE (FIG. 2) • Install this valve on the COLD water pipe to the WATER kitchen sink (FIG. 2). • This valve has a cutting pin and will make its own hole in copper or plastic pipe. To install on iron pipe, you have to drill a 1/8" diameter hole for the cutting pin. NOTE: VALVE use COLD WATER PIPE CHECK LOCAL CODES FOR APPROVAL SHOCK, USE A HAND OR BATTERY POWERED DRILL ONLY TO MAKE THE HOLE.
- HOW TO INSTALL YOUR HOME DRINKING INSTALL THE DRAIN WATER SYSTEM - ADAPTER • Use FIG. 3 and the following guides. Note: Consult plumbing 1. a plumber if you are not familiar with procedures• Use a ferrule and nut to assemble the drain tubing connector to the drain adapter. Turn the connector to about 45 ° from the 12:00 position, as shown (to 10:00 or 2:00 position). Tighten the nut securely. 2. Carefully disassemble the sink drain pipe and clean the tailpiece to assure a leak-tight fit• 3.
- HOW TO INSTALL YOUR HOME DRINKING ASSEMBLE FAUCET B. ASSEMBLE AND INSTALL FAUCET WATER SYSTEM - - continued (FIG. 4) 1. Remove the hex nut, and all other parts shown in the dotted line box, FIG. 4. FAUCET AND BASE ASSEMBLED 2. Insert the faucet stud through the top gasket and faucet base. Then, replace the hex nut and tighten. DO NOT OVERTIGHTEN AND BREAK THE FAUCET BASE. NOTE: The faucet that are not used. may include some small faucet body parts 3.
- HOW TO INSTALL YOUR HOME DRINKING WATER SYSTEM tighten the nut. NOTE: Cut tubing as needed for neat appearance, but keep long enough to alllow easy service of the RO system. 7. If needed, cut the 1/4" tubing (marked "1/4" BARB ON FAUCET") to length. Then, push the end all the way onto the 1/4" barb fiting on the faucet. faucet base -_ 1/4" barb fitting 3/8" barb fitting 8. Take the 27" long separate piece of 3/8" tubing and pass 1 end down through the faucet support.
- HOW TO INSTALL YOUR HOME DRINKING MAKE REMAINING RO CONNECTIONS B. CONNECT TUBING, ING CONNECTOR FAUCET - continued C. CONNECT TUBING Use the tubing insert, ferrule TO DRAIN TUB- SANITIZING, D. Fasten the faucet wire connectors out of the way. PRESSURE A. DO THE SANITIZING PROCEDURES, 15. THEN, CONTINUE WITH STEP B. TO WATER - SUPPLY and nut, at the water supply saddle valve, to fasten the remaining 1/4" tubing (marked "WATER SUPPLY"). Tighten the nut with a wrench. Looking at FIG.
- HOW TO INSTALL YOUR HOME DRINKING the RO system. At that time, carefully check all fittings and tubing connections for any water leaks. Correct leaks if any are found. 2. Allow the bladder to fill again for about 4 hours, then open the faucet and empty. After 4 purgings, the system is ready to make product water for your use, - HOW YOUR HOME DRINKING WATER SYSTEM WORKS supplywater IN Water from the cold supply pipe saddle valve is directed through 1/4" tubing, to the electronic box.
- HOW YOUR HOME DRINKING WATER SYSTEM WORKS POSTFILTER - continued light comes on after 6 months, or after 900 gallons of product water use. water. High quality drinking water flows from the postfilter and to the faucet. NOTE: Before going to the faucet, product FLASHING water passes through the electronic box and remaining TDS is measured by a sensor. FAUCET dispenses - The sinktop or countertop faucet the drinking water.
- CARE OF YOUR HOME DRINKING PREFILTER CARTRIDGE - You must replace the prefilter cartridge often to protect the RO membrane from being destroyed by chlorine, and/or from plugging with sediments from the water supply. If you have chlorine in the water, replace the cartridge at least every 6 months. If the prefilter cartridge plugs with sediments, water flow intothe RO system drops, slowing the making of quality RO water. The RO membrane may also begin to plug with sediments.
- CARE OF YOUR HOME DRINKING RO MEMBRANE CARTRIDGE - The useful life for the RO membrane to become useless. A small, cone-shaped screen is positioned over the flow con- of the membrane cartridge depends mostly on the pH (see page 17) of your supply water. The lower the pH, the longer the membrane will last. For example, if the feed water has a pH of about 7.0, the trol (FIG.
- CARE OF YOUR HOME DRINKING 7. Install the RO housing, rotate 900 clockwise push downward 8. Replace the tank shutoff valve and rotate 900 to lock. 9. Using the o-ring seal, replace valve. 10. DO THE SANITIZING CEDURES, PAGE SANITIZING and to lock in place. the vacuum AND PURGING relief PRO- 1. BE SURE 10. SHUTOFF SERVICE marks to properly WATER SUPPLY TO THE OFF, AND THE RO FAUCET RO IS IS OPEN. torque Fig, 9, page 13. 3.
- CARE OF YOUR HOME DRINKING WATER SYSTEM - RO CARE GUIDE MODEL RO 2000 WITH MONITOR IMPORTANT: BEFORE DOING THE FOLLOWING MAINTENANCE, BE SURETO RELIEVE PRESSURE AND ALLOW AIR TO ENTER THE TANK, STEPS 1, 2 AND 3, PAGE 12. t. Replace the prefilter cartridge and postfilter when the amber "FILT" light begins to flash while taking product water from the RO faucet. Clean or replace the flow control and screen. and replace the batteries in the electronic control box. 2.
- DIMENSIONS / SPECIFICATIONS - •=-- 8_ 1/8,,--.-_ 21" Supply water pressure limits ...................................... 40-125 PSI Supply water temperature limits ..................................... 40-100OF Maximum total dissolved solids (TDS) ............................... 2000 PPM Maximum water hardness @ 6.9 pH .................................. 10 GPG Maximum iron, manganese, hyd. sulfide .................................... 0 Chlorine in supply water (SEE PAGE 4) ...........................
- REPAIR PARTS WaterWorks _ HOME DRINKING ] WATER SYSTEM Undersink DRAIN II 36 -----_(_ ADAPTER I 35 ---'-'-"_(_;J[ I"'---,_ 5 34 "'"""_ _ 33 .-.----.-_ "_ Reverse Osmosis MODEL RO 2000 37 32 --"--'-_,_ 27 i O I I II 1 TO 7 AIRGAR 1/4" BARB i• 24 _ 26 \ Z3 ..... _ ....... "'\ I / ""-L I 19 18 ...,..
- REPAIR PARTS WaterWorks TM KEY NO. PART NUMBER 1 7205465 2 HOME DRINKING WATER SYSTEM Undersink Reverse Osmosis MODEL RO 2000 KEY NO. PART NUMBER Faucet 27 7167764 Flow Control 1260600 Washer 28 709503O Cone Screen 3 7207734 Adaptor (Includes key nos. 2 & 4) 29 4 9043201 Nut, 3/8" Tubing 3O 7115610 O-ring Seal, 3-1/8" x 3-3/8" O.D.
- REMOTE INSTALLING RO ASSEMBLY, INSTALLATION AND/OR SUPPLY Longer lengths of tubing are available from Sears (see page 19) for installingthe RO assembly, and/or water supply saddle valve away from the RO faucet. Examples: In the basement, under the kitchen or bathroom sink. In a closet or room nearby the kitchen or bathroom. You can run the RO assembly drain tubing directly to an open drain and bypass the faucet.