Installation Guide
4 
DRAIN CONNECTIONS 
Follow all industry standard plumbing procedures for installation of overflow and drain. 
Care must be taken to insure watertight connections. The diagrams below are typical drain 
installations for Watertech Whirlpool Baths. For best results follow the instructions provided by 
the manufacturer of your drain 
TILE FLANGE 
The tile flange is an aluminum angle designed to allow a 
watertight seal between the tub surround and the tub. 
The tile flange is typically positioned behind the tile backer 
board and is attached to the tub surface with the high tack 
foam tape provided as part of the flange. Tile or other 
waterproof material is usually installed over the backer 
board and flange and finished with a caulk joint at the tub. 
WHIRLPOOL PUMP 
ELECTRICAL REQUIREMENTS: 
120 VOLT AC 
20 AMP DEDICATED CIRCUIT 
GFCI OUTLET 
ALL BRANCH CIRCUITS TO THE 
WHIRLPOOL , AND ALL ELECTRICAL 
COMPONENTS MUST BE GROUNDED. 
ALL ELECTRICAL CONNECTIONS TO YOUR TUB 
MUST BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE 
WITH THE NATIONAL ELECTRICAL CODE AND ANY LOCAL CODES. 
Should your pump ever need servicing, you can easily remove 
it from the tub by unscrewing the quick disconnect unions at the 
top and front of the pump housing and remove the pump 
mounting screws. After servicing it can be returned to service 
by reversing the procedure. 
Thoroughly check for leaks after reinstallation. 