Specifications

Waters Network Systems User’s Manual Page 14
PS-2126M-POE
4.0 Network Applications
There are three ways to access switch management functions:
1. RS-232 serial port connection (CLI)
2. Telnet
3. Web
Note: Before accessing management functions through Telnet or the Web, you must modify the
IP address, subnet mask, default gateway and DNS through the RS-232 connection.
4.1 Using the RS-232 Serial Port Connection
To configure the switch via the RS-232 serial port connection, follow these steps:
1. Connect the serial cable included with your switch to your workstation.
2. Connect the serial cable to console connector on the back of your switch.
3. Run the terminal emulator (Example: HyperTerminal) using the following settings.
a. Baud rate (bits per second): 57600
b. Data bits: 8
c. Parity: N
d. Stop bits: 1
e. Flow control: None
4. When you complete the connection, press the Enter key.
5. Turn on the switch.
6. The default login is:
a. Username = admin
b. Password = admin
4.2 Configuring IP, Subnet Mask and Default Gateway
The default settings for your switch are listed in the following table:
Default Value PS-2126M-POE
IP Address
192.168.1.1
Subnet
255.255.255.0
Default Gateway
192.168.1.254
Table 4-1
You may either change the IP address of the switch or change the IP address of your
workstation. To change the IP address of the switch, via the console connection, you will have
to use the CLI command listed below. A complete list of CLI commands is in Section 6.0 of this
manual.