Specifications
Waters Network Systems 2800M/MR User’s Manual Page 99
Parameter description:
Port No.:
Choose the port number. Valid ports are 1~26.
Rate:
Rate is used to set the limit of Ingress bandwidth for the port. Incoming traffic will be discarded
if the rate exceeds the value you set up in Data Rate field. Pause frames are also generated if
flow control is enabled. The format of the packets are limited to unicast, broadcast and multicast.
Port 1~24 port numbers range from 66~102400. Port 25~26 port numbers ranges from
66~1024000 with the minimum unit of 1. Default value of Port 1~24 is 102400 and Port 25~26 is
1024000.
Function name:
Egress Bandwidth Setting
Function description:
Egress Bandwidth Setting function is used to set the limit of Egress bandwidth for each port.
Figure 5.61 – Egress Bandwidth Control
Parameter description:
Port No.:
Choose the port number. Valid ports are 1~26.
Rate:
Rate is used to set limit of Egress bandwidth for the port. Packet transmission will be delayed if
the rate exceeds the value you set in the Data Rate field. Traffic may be lost if egress buffers
run full. The format of the packets are limited to unicast, broadcast and multicast. Port 1~24 port
numbers range from 66~102400. Port 25~26 port numbers ranges from 66~1024000 with the
minimum unit of 1. Default value of Port 1~24 is 102400 and Port 25~26 is 1024000.