Specifications

Waters Network Systems 2800M/MR Users Manual Page 45
Figure 5.15 – Detail Counter
Each data field is 20-digits. If the counting overflows, the counter will be reset and counting will
be restarted. The data is updated based on the time interval defined by the user. The valid
range is three to ten seconds. The refresh interval is used to set the update frequency. Default
update time is three seconds.
Function name:
Detail Counter
Function description:
Displays the detailed number of each port’s traffic. In Figure 5.14, the window shows all counter
information for one port at a time.
Parameter description:
Rx Packets:
The number of packets received.
Rx Octets:
Total received bytes.
Rx Errors:
Number of bad packets received.