Command Level Description Example
[Systemlog|
SMTP|Both]
event
systemlog
[Link-UP|Link-
Down|Both]
I Set port event for system log switch(config)#interface
fastethernet 3
switch(config-if)#event
systemlog both
event smtp
[Link-UP|Link-
Down|Both]
I Set port event for SMTP switch(config)#interface
fastethernet 3
switch(config-if)#event smtp
both
show event P Display event selection switch#show event
no event
device-cold-
start
G Disable cold start event type switch(config)#no event
device-cold-start
no event
authentication-
failure
G Disable authentication failure
event type
switch(config)#no event
authentication-failure
no event X -
-ring-topology-
change
G Disable X- ring topology event switch(config)#no event X -
-ring-topology-change
no event
systemlog
I Disable port event for system
log
switch(config)#interface
fastethernet 3
switch(config-if)#no event
systemlog
no event smpt I Disable port event for SMTP switch(config)#interface
fastethernet 3
switch(config-if)#no event
smtp
show
systemlog
P Display system log client &
server information
switch#show systemlog
The following table lists the SNTP Commands.
Command Level Description Example
sntp enable G Enable SNTP function switch(config)#sntp enable
sntp daylight G Enable daylight savings time.
If SNTP function is disabled,
this command can’t be
applied.
switch(config)#sntp daylight
sntp
daylight-period
G Set period of daylight savings
time. If SNTP function is
switch(config)# sntp
daylight-period