Operating instructions

The Cube Technical Manual - Version 1, May 2014
24 25
Technical Specifications
and Warranties
SAFETY
Subject to the standard terms and conditions of sale (a copy of which has been
provided to you), neither Waterlogic International Limited (“Waterlogic”), nor any
affiliated companies shall be liable for any damage which could affect, directly or
indirectly, any person or property.
Please be aware that any warranties accompanying the sale of our products will be
invalidated by any of the following:
• Incorrect installation
• Incorrect use of the Cube
• Unsuitable electrical and water supply
• Major short-coming of maintenance
• Technical interventions or alterations of an unauthorised nature
• Adoption and use of unapproved spare parts
• Any repair by untrained personnel
Waterlogic has a policy of constant and continual improvement and therefore
reserves the right to change specifications without prior notice, other than in the
case of significant changes.
Description Cube (120V) HCA Cube (230V) HCA
Machine Size
296mm(W) x 425mm(D) x
375mm(H)
296mm(W) x 425mm(D) x
375mm(H)
Machine Weight 18Kg 18Kg
Power Supply 120 Volt / 60Hz 220-240 Volt / 50Hz
Heater 500W / 4.2A 500W
Fan 2W 2W
Compressor 120W / 1.7A 120W
UV Lamp 13W / 0.3A 13W
Unit Total 635W / 6.2A 635W
Refrigeration Gas R134a 55g / 1.94OZ 55g / 1.94OZ
Cold Tank Capacity 1.4L 1.4L
Hot Tank Capacity 1.3L 1.3L
Water Connection 1/4 Hose 1/4 Hose
Minimum Water Pressure
Bar (Megapascal)
3.77 (0.377) 2.6 (0.26)
Maximum Water Pressure
Bar (Megapascal)
6.0 (0.6) 4.14 (0.414)
Recommended Water
Pressure Bar
(Megapascal)
4.35 (0.435) 3.0 (0.3)
Minimum Incoming Flow
Rate (litres per minute)
1.0 lpm 1.0 lpm
Dispensing Flow Rate 1.3lpm 1.3lpm
Cold Water Temperature
Range
5°C - 15°C / 41°F - 59°F 5°C - 15°C / 41°F - 59°F
Hot Water Temperature
Range
80°C - 95°C / 17F - 203°F 80°C - 95°C / 17F - 203°F