WL Cube Firewall Technical Manual VERSION 1
Technical Manual Declaration Waterlogic International Ltd Welcome to your new Waterlogic machine. This Technical Manual is to help you get great tasting water cup after cup by making the most of the product’s features.
Machine Overview THE CUBE HOT TANK The hot water temperature is controlled by a Microprocessor and is set to 87°C for standard and 95°C for extra hot. A thermal cut out is fitted to the Hot Tank to prevent overheating. Setting the hot water temperature to 87°C also helps stop scale forming in the hot tank, prolonging the 500 Watt element and the hot tank. The capacity of the hot tank is 1.3 liters. The Cube is available in the following option: a) Cold, Hot, Extra Hot and Ambient.
UV LAMP The UV light is a 13 Watt germicidal lamp at a wavelength of 253.7 NM, which is very efficient at destroying bacteria in water. The UV lamp is situated in the Firewall Chamber surrounded by a quartz spiral that attains NSF standard 55 purification of water. The UV lamp must be replaced at 12 months intervals or when indicated by the warning lights, and the quartz spiral cleaned by using an ultrasonic bath if needed. PLASTIC PANELS The molded panels are made from recyclable ABS plastic.
Pre Delivery Inspection Procedures (PDI) WL Cube Flow Diagram Cold, Hot & Ambient CAUTION: Only competent trained technicians should work on Waterlogic products. Waterlogic units may weigh over 25KG. We recommend caution when lifting. Packing materials could present a trip hazard. Keep them off the floor. Take care not to allow the power lead to get wet. If the lead gets wet it must not be used.
Pre Delivery Inspection Procedures (PDI) Installation Procedures 1. Remove packing straps and unpack unit and visually inspect for any damage. (Report any defects to Waterlogic as soon as possible). 2. Place the unit on a suitable work bench. 3. Open the top cover by removing the two screws that fix it in place. 4. Visually inspect all electrical connections and power lead. 5. Visually inspect all water connections. 6.
. The hot water tank now needs to be filled, this is done by selecting the hot water icon, then followed immediately by pressing and holding the main dispense button until the tank has completely filled and water is being dispensed. Flush through 5 litres of water by continuing to select the hot option. Then repeat this process again for the cold option. 8. After making sure the hot tank is full of water then turn on the green heater and compressor switch at the rear of the machine. 9.
Operating Instructions ENERGY SAVING FEATURE The Cube has an energy saving feature that minimizes power consumption when the machine has not been operated for 3 hours. If the sleep mode on the Cube has been deactivated, the machine will automatically enter sleep mode after 72 hours of no use. The Cube can be taken out of sleep mode by touching any of the buttons. Please note the hot tank will take 10-12 minutes to reach optimum hot temperature after the machine has been taken out of sleep mode.
Maintenance and Servicing • The Cube must be serviced every 12 months, but we strongly recommend the UV lamp and filters be changed every six months. • The Cube may require any calcium build up in the hot tank to be removed, this depends on the local water conditions. • No paperwork or cleaning records should be stored inside the Cube. • To reset the filter timer, hold down the hot and cold icons simultaneously for 10 seconds.
4. Remove the top cover from the Cube by undoing the two screws located at the back of the machine, then slide the panel backwards and lift up. 5. Take out the filter by un-clicking the loop at the top of the housing and pulling it in an upward motion. If there are two filters in the machine then both of these need to be removed. 6. Unscrew the filter housing(s) and remove the filter cartridge, place this to one side as this will need to be re-fitted this once you have completed the sanitising procedure. 7.
ADVISORY ICONS selecting the cold option until the water stops being dispensed. Isolate the power to the machine by switching the red switch at the rear of the machine off and removing the power lead. 12. Remove the top cover from the machine. Then take out the filter(s) and unscrew the housing, pour the excess water down the drain and re-fit the cartridge. 13. Re-fit the filter(s) into the machine pushing it firmly into place.
FAULT FINDING All fault finding procedures must be carried out by a technician trained by Waterlogic International or their nominated distributor. Please take great care and suitable health and safety measures when fault finding on live electrical parts. 1. No flow of water: Ensure that there is a water supply to the Cube from the building and that the installation isolation valve is turned on.
Technical Specifications and Warranties SAFETY Subject to the standard terms and conditions of sale (a copy of which has been provided to you), neither Waterlogic International Limited (“Waterlogic”), nor any affiliated companies shall be liable for any damage which could affect, directly or indirectly, any person or property.
End of Life Electrical Wiring Diagram 120V Non Eu Countries At the end of this products life, please ensure that it is disposed of in an environmentally friendly manner which is in line with your Country requirements/guidelines. WEEE (EU ONLY) Please be aware that our products are covered by the Waste Electrical and Electronic (WEEE) directive (2002/96/EC). The symbol shown above denotes that the product should not be disposed of with general/household waste.
Electrical Wiring Diagram 230V Dip Switch Setup THE CUBE MAIN PCB DIP SWITCHES 1 & 2 WITH INSTRUCTIONS DANGER HIGH VOLTAGES PRESENT ON THIS PCB CARE MUST BE TAKEN WHEN LIVE TESTING Dip switch 2 Dip switch 1 The Cube Technical Manual - Version 1, May 2014 28 29
Dip Switch Setup When reading this document please note the white coloring on the diagrams indicate the required position of the switch to determine the setting. DIP SWITCH 1 SETUP DP1 UV 1 DIP SWITCH 2 SETUP DP2 FILTER 2 3 C-TEMP 1 2 H-TEMP 3 4 H-SLP CS 3M 5˚c 80 ˚c ON US 6M 10˚c 87 ˚c OFF 12M 10˚c 87 ˚c NO 15˚c 95 ˚c UV SETTING FILTER TIMER SETTING • CS = CDS Sensor (Used in Europe) • US = UV Sensor A combination of dip switches 2 & 3 is used to enter this setup.
Wetted Parts List Hot, Cold and Ambient 48 47 46 45 44 43 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 9 1 12 2 3 4 56 7 8 42 20 10 11 26 13 14 15 16 17 18/19 21 22 23 24 25 N° Part Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 JG Bulkhead Connector Union 1/4" * 1/4" JG LLD PE Tube - Blue O.D.1/4" JG LLD PE Tube - Blue O.D.
Wetted Parts List Hot, Cold and Sparkling N° Part Description 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Silicon Tube 5/16" for hot water JG End Stop 1/4" JG LLD PE Tube - Blue O.D.1/4" JG Equal Tee Connector 1/4" JG 1/4" STOPPER JG UK JG Equal Tee Connector 1/4" JG LLD PE Tube - Blue O.D.1/4" JG LLD PE Tube - Blue O.D.1/4" Solenoid Valve 24 DC (Single Spring Load) JG Equal Tee Connector 1/4" JG Stem Elbow Connector 1/4" * 1/4" JG Equal Tee Connector 1/4" JG LLD PE Tube - Blue O.D.
Main Parts List WL Cube Mains Parts Illustration 41 42 44 45 46 47 48 49 50 43 40 39 38 37 36 26 27 28 29 30 31 32 33 35 34 25 24 23 22 21 20 19 18 17 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 N° Part Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 WL Cube Side panel left -Silver Mark IV Al (Mirror/no gauze/Spout 18mm) for CUBE WL Cube FW fixing bracket WL Cube Front frame panel-Black WL Cube Front cover -Silver WL Cube Spout assembly bracket-Silver W
N° 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Part Description Drain valve cap only (for 5/16" & 1/4" size) Electronic fixing Bracket WL Cube WL Cube Top Cover- Black 5/16-1/4 Reducing Straight Connector Filter Bracket CBC 1 Micron 10" Filter Ass’y-PD use-WL Label Hot & Cold Solenoid Valve 24V- 300mm CUBE 1/4" Equal Tee Connector(ST) UV 15 W Electronic Ballast (Ver.
USA, Canada and Mexico Rest of the world info@waterlogicusa.com + 1 402 884 7212 exportsales@waterlogic.com + 353 1 293 1960 Waterlogic USA, 11710 Stonegate Circle, Omaha, NE 68164 WLI Trading Ltd. Suite 4, 2nd Floor Beacon Court, Sandyford, Dublin 18, Ireland www.waterlogic.